Industrial Precision Oven

Industrial precision ovens use electric heating elements to heat the air, combined with fan circulation and temperature control systems to achieve uniform temperature regulation. They are used for processes such as curing, drying, and heat treatment, ensuring stable product quality in fields such as electronic components, chemical materials, and food processing.
Selection
When selecting, consider the temperature range and fluctuation to match the process requirements; pay attention to the impact of the inner chamber material and heating method on the samples; determine the working chamber volume based on production capacity; choose the temperature control accuracy and power specifications according to the on-site conditions; confirm safety configurations such as explosion-proofing and ventilation.

Terms

Standards

Instruments

Precision PID control technology, Temperature Fluctuation +/- 1%, mirror stainless steel liner anti-acid and alkali corrosion, combined with good air duct design to ensure Temperature uniformity, suitable for applications with high Temperature uniformity requirements.

$ 403.00

Precision PID Control Temperature Fluctuation +/- 1%, mirror stainless steel liner anti-acid and alkali corrosion, studio volume 130L, equipped with independent temperature controller interface to ensure the safety of high-value samples.

$ 649.00

Temperature control accuracy of +/- 1%, temperature resolution of 0.1 ℃, equipped with independent temperature limiting controller and RS-485 communication interface, support three-sided circulating air duct to ensure uniform and stable temperature, safe and reliable operation.

$ 751.00

Large LCD screen, Menu Operating interface, Temperature Fluctuation +/- 1 ℃, Mirror stainless steel liner for easy cleaning, Thickened box design low surface temperature, Thermal Power reduced by more than 25%.

$ 803.00

Temperature uniformity is improved by fan speed control, air duct circulation system automatically discharges water vapor, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 630.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Large diaMeter centrifugal wind wheel and optimized air duct, heat flow evenly; Temperature range RT + 5~ 250 ℃, Temperature Accuracy +/- 0.5 ℃, can work stably for a long time.

$ 1379.00

Mirror stainless steel studio, temperature control accuracy of +/- 1%, temperature resolution 0.1 ℃, equipped with independent temperature controller and RS-485 communication interface, to ensure safe and reliable operation.

$ 593.00

1000L large volume design, Temperature uniformity up to +/- 0.5 ℃, equipped with air duct circulation system automatic discharge of water vapor and over-temperature protection function, support RS485 interface connection recording device.

$ 3057.00

Control mode of fan speed is adopted to improve temperature uniformity, with over-temperature deviation protection and timing function, accurate and reliable temperature control, Temperature Fluctuation +/- 0.5 ℃, volume 620L.

$ 1948.00

Temperature range -80~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high precision and stable temperature control, to meet the needs of a variety of environment testing.

$ 7753.00

Adopt fan speed control to improve Temperature uniformity, air duct circulation system automatically discharges water vapor, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.5 ℃, support timing and over-temperature protection functions.

$ 827.00

Inner Chamber dimensions 500 * 600 * 750mm, Volume 225L, Temperature Fluctuation +/- 0.5 ℃, using air duct circulation system to automatically discharge water vapor, improve Temperature uniformity, support RS485 interface connection recorder.

$ 1069.00

Control mode of fan speed to improve temperature uniformity, automatic discharge of water vapor, temperature control accuracy +/- 0.5 ℃, mirror stainless steel liner for easy cleaning, support RS485 interface connection recording device.

$ 1734.00

Temperature range -80~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision stable temperature control, to meet a variety of industry testing needs.

$ 5771.00

Articles

The laboratory pulp wet disintegrator is used for pulp disintegration treatment.
The laboratory pulp wet disintegrator is a device used to simulate the industrial pulping process. It disperses pulp fibers into individual fibers or small fiber bundles through mechanical action, while simultaneously promoting fiber swelling and fibrillation, thereby providing standardized samples for subsequent performance evaluation.
Application of Valley Beater in Pulp Laboratory Beating
The Valley beater is a device used in laboratories to simulate industrial beating processes. It modifies the morphology of pulp fibers through mechanical action, thereby influencing paper properties. During operation, parameters such as beating pressure, pulp consistency, and beating time must be controlled, with the beating degree serving as a quantitative measure of the effect.
Comparative Study of Lovibond Colorimeter and Iron-Cobalt Colorimeter
The Lovibond colorimeter and the iron-cobalt colorimeter are two widely used visual color measurement instruments in the industrial field. Both are designed based on the principle of standard color comparison, yet they exhibit significant differences in their specific implementation methods and application standards.
Hiding power measurement: Equivalence of mass per unit area method and reflectance contrast method.
Covering power is a key indicator for evaluating the optical performance of coating materials such as paints, inks, and pigments, reflecting the material's ability to conceal the color of the substrate. Accurate determination of covering power is crucial in industrial quality control and research and development.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.