Near-Infrared Imager

Near-infrared imaging devices utilize the differential absorption of near-infrared light by substances to image and detect the distribution of sample components. They are used for measuring the thickness of plastic films, analyzing the moisture content of paper, and assessing the uniformity of ink.

Instruments

Infrared source to avoid chroma interference, built-in bubble elimination system to improve Stability, Measurement range 0-10000mg/L, accuracy +/- 2% FS, support automatic cleaning and RS485 communication.

$ 667.00

Infrared source to avoid chroma interference, built-in bubble elimination system to improve Stability, Measurement range 0~ 200mg/L, accuracy +/- 2% FS, support automatic cleaning and RS485 communication.

$ 780.00

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Granite structure ensures Stability, Measurement accuracy of (3 + L/200) μm, Repeatability of 0.002mm, Equipped with high resolution CCD and adjustable LED Illuminant to avoid workpiece deformation.

$ 9488.00

Measurement accuracy of (3 + L/200) μm, equipped with high resolution CCD and adjustable LED Illuminant to avoid thermal deformation of the workpiece.

$ 12862.00

Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.

$ 2494.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.

$ 2494.00

Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, accuracy ≤ +/- 2%, support a variety of signal output and remote transmission, with overvoltage, lightning protection and other protection functions to ensure stable and reliable monitoring.

$ 2368.00

Full marble construction ensures Stability, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Illuminant to avoid thermal deformation of workpiece, Support Z-axis image altimetry or contact measurement.

$ 3222.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.

$ 507.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Full marble construction ensures Stability and rigidity, Measurement accuracy up to (3 + L/200) μm, Adjustable LED Ring Illuminant to avoid thermal deformation of the workpiece, Support manual operation and a variety of accessories options.

$ 2741.00

Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.

$ 153.00

Made of stainless steel, with a flow hole diaMeter of 3.0 +/- 0.01mm and a viscosity range of 7-40mm ²/s, it is suitable for testing the outflow time of Newtonian or near-Newtonian liquids and meets ISO and GB standards.

$ 143.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.