Hydraulic automatic pull-off test, the pull-off speed is stable and controllable, the accuracy is +/- 1% full scale, equipped with pull-off kit size 10-50mm, built-in rechargeable battery and 200,000 Data storage.
With 0.5 accuracy class and 1000N range, support force holding time 0-999.9 seconds can be set, integrated pull-off stop and overload protection functions, easy and reliable operation.
Adopt double guide Rod structure to ensure Stability, Maximum Measured value 5000N, Travel 220mm, support stepless speed regulation and a variety of test modes, with pull-off stop and force retention functions.
Portable design built-in lithium battery, 0-3000p range accuracy +/- 1%, equipped with 10-50mm pull-off spindle, automatic calculation of pull-off force without conversion table, aluminum alignment unit to ensure uniform testing.
Adopt low-noise stepless speed regulation motor, with a speed range of 0-500mm/min, with force holding function and four test modes, equipped with limit protection device, support pull-off stop and set force value round-trip motion.
Adopt precision automatic control data collection system, range 3000N, accuracy class 0.5, with force holding and pull off stop function, support 100 groups of test Data storage and qualified judgment statistics.
Stepping motor and High Accuracy encoder ensure mechanical stability, displacement accuracy ≤ +/- 0.1mm, speed range 10-800mm/min, support force holding and pull-off stop function, equipped with limit and emergency protection device.
Equipped with a 20mm kit and trimmer, the range covers 0-20MPa, and precise positioning is achieved through a transparent sleeve, specially designed for high viscosity coating adhesion testing.
Using stainless steel liner and top cover, microcomputer intelligent temperature controller can display setting and measurement temperature at the same time, Temperature Fluctuation +/- 0.5 ℃, with timing and over-temperature water cut-off alarm function, optional built-in circulating water pump output thermostatic water flow.
Temperature range 37~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, using stainless steel liner and microcomputer intelligent temperature control instrument, with timing function and over-temperature water cut-off alarm, can be external circulation pump output thermostatic water flow.
Adopt double guide Rod structure to ensure Stability, range 10KN accuracy 0.5, support force holding and pull-off stop function, with four test modes and adjustable speed range 0-500mm/min.
High Accuracy S type sensor accuracy of 0.5%, range 0-10KN, with pull-off automatic stop function, three operation modes optional, can directly enter the test block area display force value and strength value
Hollow self-resetting hydraulic cylinder design, maximum pull-out force 40kN, central aperture 18mm, digital pressure Gauge directly read the force value and with storage query function, simple operation suitable for on-site use.
Maximum pull-out force 50kN, center aperture 18mm, hollow self-resetting digital display integrated structure, can directly read the force value, with peak holding, storage, backlight and automatic shutdown functions, simple and reliable operation.
Hollow self-resetting hydraulic cylinder design, maximum pull-out force 20kN, digital pressure Gauge with peak holding, storage and query functions, resolution up to 0.001KN, Indication Error ≤ +/- 1% F. S, simple and portable operation.