Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.
Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.
Using the magnetic induction method, the measurement range is 0~2000 μm, with an error of ±5%, a resolution of 0.1 μm. It supports separate probes and low-voltage alerts, and is suitable for various types of coatings.
Measurement range of 0-1250μm using eddy current principle, with single and continuous two measurement modes, support metric imperial unit conversion, with split Probe and RS232C interface, providing Automatic calibration and matrix recognition function.
Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.
Using magnetic Induction and eddy Current dual principle, measurement range 0-2000μm, accuracy +/- 3%, equipped with ruby probe wear and corrosion resistance, support automatic identification of iron-based and non-iron-based materials, no need to calibrate easy to operate.
Measuring methods of magnetic Induction and eddy Current, covering 0-1500 μm range, resolution up to 0.1 μm, support continuous and single Measurement mode, statistical function and 500 sets of data storage, suitable for different curvature radii and substrate Film thickness scenes.
Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.
Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.
Using magnetic and eddy current two thickness measurement methods, Measurement range 0-1250μm, with automatic identification of iron and non-iron matrix function, support single point and two point calibrating, with power supply undervoltage indication and statistical function.
Using magnetic Induction principle to achieve 0-6000μm large-range measurement, the error is only +/- 3%. With continuous single double measurement mode, support four-point statistical function, large-capacity storage of 2000 sets of data, automatic identification of matrix material.
Hardness and corrosion resistance, wet film thickness adjustment range 0-4500 μ m, magnetic suction design for quick replacement and cleaning, differential head accuracy of +/- 2 μ m to ensure film uniformity.
Using magnetic Induction and eddy current double thickness measurement method, Measurement range 0-1250μm, error +/- 3%, automatic identification of iron and non-iron matrix, with statistical function and undervoltage indication, easy to operate.
Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500 μm, with temperature compensation function, support continuous fast and High Accuracy Measurement mode, can store 500 sets of data and automatically filtrate outliers.
Adopt magnetic Induction principle measurement 0-10mm thickness range, resolution up to 0.1μm, Probe wear-resistant more than 500,000 times, suitable for -10-50 ℃ environment, error range +/- 3%, stable and fast test.