Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.
Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
Adopt TMHM equilibrate Conditioning method, temperature fluctuation +/- 1.0 ℃, humidity deviation +/- 3% RH; with 100 sets of program capacity and P.I.D automatic calculation function, ensure stable and uniform heat preservation Humidity, support multi-stage programmable operation.
The 7.0-inch large screen is easy to operate, equipped with a French Taikang Compressor unit, Temperature Fluctuation ≤ +/- 0.5 ° C, humidity deviation + 2, -3% R.H, independent temperature and humidity system to improve efficiency.
Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with independent temperature limit alarm and double-decked Glass observation window to ensure safe and reliable testing.
Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.
Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.
Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.
The 7.0-inch large screen is easy to operate, equipped with French Taikang fully enclosed Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2, -3% RH, support 0~ 9999 minutes timing and independent temperature limit alarm.
Using fluorine-free environmental protection refrigeration system, temperature control accuracy of +/- 0.5 ℃, equipped with independent temperature limit alarm and P.I.D automatic calculation function, to ensure that the thermal insulation Humidity control is stable and safe, easy to clean and maintain.
Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.
Humidity Control Range 35-95% RH, Input Power 8050W, Fluorine-free design, multi-stage programmable PID controller and imported 304 mirror stainless steel liner, with independent temperature limit alarm system.