Temperature-Controlled Thermostatic Bath

The constant temperature bath maintains stable liquid temperature inside the bath through heating or cooling systems. It is used for constant temperature treatment of laboratory samples, instrument calibration, and material testing to ensure consistent experimental conditions.
Selection
When selecting, consider that the temperature range must cover experimental needs, precision must match testing standards, tank capacity should accommodate sample size, stability should meet long-term operation requirements, and materials should be corrosion-resistant and easy to clean.

Terms

Standards

Instruments

Provide a uniform and constant field source with controlled temperature, which can be used for constant temperature experiments or tests on samples, and can also be used as a heat source for direct or auxiliary heating.

$ 2784.00

It has two oscillation functions of reciprocating and rotating, temperature control accuracy +/- 1 ℃, stepless speed regulation range start~ 300rpm, spring test bottle clip supports a variety of comparison tests, smooth operation and easy operation.

$ 483.00

The internal resistance range is less than or equal to 5mΩ, the peak current is up to 1000A, and it is automatically controlled by PLC. It has the function of temperature monitoring and can set short-circuit stop conditions to ensure accurate and reliable test data.

$ 1632.00

With reciprocating and rotating two oscillation modes, temperature control accuracy +/- 1 ℃, Oscillation Frequency start~ 300rpm, stepless speed regulation smooth operation, stainless steel cavity corrosion resistance, suitable for a variety of comparative tests.

$ 601.00

Temperature control accuracy of +/- 0.5 ℃, Oscillation Frequency start to 300rpm, the use of oxygen hole design to ensure sufficient thermostatic working Chamber oxygen, multi-functional spring bottle rack to support a variety of comparative experiments, easy and safe operation.

$ 483.00

Temperature control accuracy of +/- 1 ℃, Oscillation Frequency start to 300rpm, using rotary oscillation mode, pendulum amplitude of 20mm, stepless speed regulation smooth operation, inner cavity stainless steel material corrosion resistance, suitable for a variety of contrast specimens foster.

$ 483.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

The 24-hole design is compatible with the testtube with a diaMeter of less than 12mm, the maximum Operating temperature is 100 ° C, and the electronic ice box and intelligent thermostatic metal Bath module are optional to meet different temperature requirements.

$ 148.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Temperature control accuracy of +/- 0.5 ℃, Temperature Uniformity +/- 0.5 ℃, with over-temperature protection and automatic fault detection function, transparent cover design to reduce experimental errors, module replacement is convenient.

$ 474.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.