Nitrogen Drying Oven

Nitrogen drying ovens create a low-oxygen environment by injecting inert nitrogen gas to displace the air inside the chamber, combined with a heating system to accelerate the drying of materials. They are used to prevent oxidation-prone samples from deteriorating during the drying process and are commonly employed for oxygen-free drying of electronic components and chemical materials.
Selection
When selecting, pay attention to the sealing of the chamber to ensure nitrogen retention capability. Determine the volume range based on sample size, match temperature uniformity according to material temperature resistance requirements, choose manual or automatic gas control mode based on the experimental process, and consider explosion-proof design for handling volatile samples.

Terms

Standards

Instruments

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.

$ 493.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Adopt microcomputer temperature control technology, Temperature Fluctuation +/- 1% ℃, Vacuum Level < 133Pa, equipped with inflatable port to supplement inert gas, suitable for rapid drying of heat-sensitive and easy analysis substances, the box door adopts tempered Glass explosion-proof design.

$ 1203.00

Cuboid studio improves volume utilization, drying time is reduced by more than 40%; Temperature range RT + 10~ 200 ℃, Vacuum Level 133Pa; double-decked Glass door is easy to observe, can be filled with inert gas anti-oxidation, stainless steel liner is durable and easy to clean.

$ 746.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Air disturbance technology is used to simulate indoor air flow, equipped with 24 independent sample Chambers to prevent cross-contamination, the drying Temperature range is adjustable at RT-50 ° C, and the outer exhaust air is purified without affecting the environment.

$ 3173.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
How to Choose an Electric Hot Air Drying Oven? Read This Guide to Avoid Pitfalls
This article explains how to choose an electric air drying oven, with key performance parameters including temperature range, fluctuation, uniformity, heating rate, and working chamber size, which directly affect experimental outcomes.