Milk RheoMeter

The milk rheometer measures the deformation and flow resistance of liquids under force through rotation or oscillation, reflecting properties such as viscosity and elasticity. It is used to detect the consistency stability in dairy product processing and guide the adjustment of process parameters such as homogenization and sterilization.

Instruments

With 0~ 35% soy milk concentration Measurement range, accuracy +/- 0.3, support automatic temperature compensation and user-defined zero point, anti-light interference design, adapt to a variety of environments.

$ 304.00

Glass electRode design, pH Measurement range 0.00~ 12.00, accuracy +/- 0.05pH, battery life up to 1000 hours, compact and portable for field use.

$ 299.00

Adopt swirl/spin vibration mode, vibration frequency 250 +/- 15 rpm, vibration amplitude 3 +/- 0.1mm, built-in micro printer supports fast output results, with stable embedded system and network connection ability.

$ 2010.00

Equipped with 7-inch Touchscreen, easy to operate, support stepless speed measurement and viscosity automatic conversion, measurement range 1~ 75000000mPa.s, gigabit network port to ensure fast and reliable data transmission.

$ 3244.00

The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.

$ 683.00

Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.

$ 11125.00

The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.

$ 683.00

The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.

$ 683.00

The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.

$ 683.00

The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The rotor shear rate is 2.0N, the sample volume is only 100 μL, the applicable viscosity range is 500~ 1000000mPa · s, the accuracy is +/- 2% F. S, suitable for processing a variety of fluid samples.

$ 683.00

The shear rate is 13.3N, the sample volume is 24μL, the applicable viscosity range is 75~ 150000mPa · s, the measurement accuracy is +/- 2% F. S, and it is suitable for a variety of fluid tests.

$ 683.00

Shear rate 2.0N, sample volume 1700μL, applicable viscosity range 32-63000mPa · s, accuracy +/- 2% F. S, suitable for a variety of fluid measurement.

$ 683.00

Using automatic temperature compensation technology, Measurement range 0-85% glucose, accuracy +/- 0.2%, only 1.5 seconds to quickly display the results, IP65 waterproof design is suitable for a variety of environments.

$ 567.00

Articles

Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Melt Flow Indexer and Torque Rheometer in the Evaluation of Processing Properties of Thermoplastic Resins
This article introduces the differences and selection methods between melt indexers and torque rheometers in evaluating the processing properties of thermoplastic resins.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Capillary Rheometer for Determining the Shear Viscosity Curve of Hot Melt Adhesives