ISO Standard Color Assessment Cabinet

The ISO color light box provides a stable lighting environment by simulating standard light sources (such as D65 daylight and A light source) and uses visual comparison to evaluate color consistency of samples. It is used for color quality control in industries such as coatings and plastics, ensuring accurate color judgment under different lighting conditions.
Selection
When selecting, pay attention to the standard light source type of the light box configuration, which should match industry requirements. The illumination uniformity should be stable without flickering, and the neutral gray coating on the inner walls should avoid interfering with color perception. Regularly calibrate for light source attenuation, ensure the box size is suitable for the samples to be tested, and ensure the operating interface aligns with daily inspection habits.

Terms

Standards

Instruments

Double light source in line with ISO3664 international standards, color rendering index up to 98, with light source Timer, all-metal structure, large folio size easy to operate, accurate proofreading Color deviation.

$ 1784.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

Equipped with five Illuminant system, supports D65, TL84 and other Standard light sources, the interior is coated with Moncel gray N5.5, the width is 60cm, and the multi-point Illuminant observation system enhances the accuracy of color evaluation.

$ 4022.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

Imported aluminum surface reflector and uniform light cover, good light uniformity, CRI ≥ 95, Color temperature 6500K, can open the design for easy replacement of lamps, behind the hook and load-bearing steel chain for easy hanging.

$ 557.00

Using high color rendering index CRI = 98 D65 light source, equipped with 4 36W lamps and light source Timer, all-metal structure to ensure stable and uniform light, in line with ISO3664 international standards.

$ 1735.00

Configuration of 6 Standard light sources including D65 and UV Illuminant, equipped with 45 degree observation station to achieve 45/0 observation conditions, no need to warm up without flashing, high luminous efficiency Color evaluation fast and reliable.

$ 1171.00

Equipped with 18 standard color scale solution, prepared according to GB/T1722-92 standard, using an inner diaMeter of 10.75mm Glass testtube, Color comparison is carried out in the Color Assessment Cabinet to ensure accurate measurement results.

$ 136.00

Standard light source without preheating, can automatically switch and record the use of time, the use of composite engineering plastic baseplate to ensure ten years without yellowing, support Metamerism detection function.

$ 396.00

With high color rendering index CRI = 98 and dual light source design, it provides a variety of color temperature options such as D65, D50, TL84, etc. With light source Timer, uniform lighting and convenient lamp replacement.

$ 783.00

Standard light sources covering 6500K to 2700K Color temperature range, support UV detection; no need to warm up and open immediately, low energy consumption without heating; Illuminant use time can be displayed, with 45 ° standard stand optional.

$ 315.00

Standard light sources, color rendering index up to 98, all-metal structure to ensure durability, large folio size easy to operate, with light source Timer function, inclined design in line with visual observation habits.

$ 1461.00

With high color strength index CRI = 98 and all-metal material, equipped with D65 and D50 dual light sources, it can simulate different lighting conditions, provide uniform lighting and stable structure to ensure accurate and reliable color evaluation.

$ 1848.00

Adopt D65 light source in line with ISO3664 international standards, color rendering index up to 98, equipped with 36W lamp and light source Timer, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1655.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
Tensile strength testing machine measures the tensile properties of paper.
The tensile strength tester is used to determine the tensile properties of paper by simulating the stretching process to obtain key parameters such as tensile strength and elongation at break. The testing follows standards such as ISO and GB to ensure reliable results.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Application of Whiteness Meter in the Evaluation of Paper Brightness and Visual Comfort
The whiteness meter quantifies the brightness and whiteness of paper by measuring its reflected light characteristics, following international standards such as ISO to ensure comparability of results. The brightness of paper affects visual comfort, and moderate whiteness can enhance the reading experience, but excessive whiteness may lead to fatigue.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.
Xenon lamp aging test chamber for testing the weather resistance of exterior wall coatings.
Xenon lamp aging test chambers accelerate the aging of exterior wall coatings by simulating environmental conditions such as sunlight, temperature, humidity, and rainfall, to evaluate their weather resistance. The tests are conducted in accordance with standards such as ISO and ASTM, controlling key parameters such as irradiance, temperature, humidity, and spray cycles.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.