The stamping sampling method is accurate and fast, the limit cutting thickness range is 0.0045~ 0.1mm, and the sampling error is only +/- 0.01mm. The special treatment die blade is used, and it can be used for 2 years without replacement. It is suitable for high-fiber paper, metal foil and other materials.
Maximum load 50Kg, Test speed 10~ 60mm/min adjustable, using pointer sensing mode, effective Travel 0~ 360mm, suitable for vertical angle disbonding test.
The measurement range is 0-20HW, the minimum measurable inner diaMeter is 10mm, the maximum sample thickness is 6mm, and the imported special steel crimping needle and high-strength pointer assembly are used. Stability is good and Hardness value conversion is supported.
Providing stable copper Ion concentration standards to ensure ElectRode Measurement accuracy, 250ml Encasement meets the daily calibrating needs of the laboratory and is suitable for a variety of copper ion detection scenarios.
The minimum test inner diaMeter is 6mm, and the maximum sample thickness is 8mm. It adopts imported special steel crimping needle and high-strength pointer assembly, which can directly display the Hardness value. Portable design is convenient for on-site use.
The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.
The minimum measurable inner diaMeter is 10mm, the maximum sample thickness is 6mm, and the imported special steel crimp and high-strength pointer components are used. It has good Stability and portability and supports Hardness value conversion.
Can detect the minimum 6mm inner diaMeter brass thin tube, range 0-20HW, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, Stability is good and support multiple Hardness value conversion.
Measurement range 0.00~ 5.00 ppm, accuracy +/- 0.05 ppm, using LED@575nm Illuminant, chemical reaction based rapid detection of copper Ion concentration, suitable for field and laboratory applications.
The copper Cup ensures durability, the diaMeter of the flow hole is 4mm with the capacity of 100ml, and the measurement time range is 0~ 150s, which is suitable for conditional viscosity determination.
Measurement range 50~ 1400kpa, accuracy ≤ +/- 0.5%, using the method of Miao Lun, support paper, aluminum foil and non-paper sheet material detection, film convex disc pressure 9mm, upper and lower disc concentricity ≤ 0.25mm.
Measurement range 0-150 seconds, copper material is durable and in line with national standards, portable design is convenient for on-site rapid detection of Coating viscosity.
Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.
Colorimetric measurement is achieved using the bischell method. Measurement range 0.00-5 mg/L, 100 tests are provided, and copper concentration is accurately determined by Color change.
Designed for Bromo Iodine Copper Ion Composite ElectRode, it provides a stable reference potential to ensure measurement accuracy, and 250ml Encasement meets the needs of routine laboratory use.