Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.
8L Tank Volume, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, equipped with maintenance-free pressure/suction pump, supports horizontal and vertical stirring to ensure uniform thermostatic.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.
Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices such as low water level anti-dry burning to ensure safe and reliable operation.
The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.
The use of non-heat centrifugal circulation pump to avoid the influence of self-heating, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection such as low water level to prevent dry burning, to ensure the stability and safety of the experiment.
8L Tank Volume, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, with low liquid level protection and automatic power failure recovery function, support internal and external circulation operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.
Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection including low water level anti-dry burning and Compressor over-current protection to ensure the safety and stability of the experiment.
8L Tank with -10~ 100 ℃ wide Temperature range, equipped with maintenance-free pressure pump to achieve two-way mixing, support single point and two point temperature calibrating, with low level protection and high temperature protection function.
Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.
The maintenance-free pressure pump is resistant to fiber metal particles, supports domestic circulation with sample Cup bracket and external circulation Viscometer jacket thermostatic, temperature control accuracy +/- 0.01 ℃ and low liquid level protection function.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
Adopt back heating structure and horizontal forced convection technology to ensure studio Temperature uniformity. Equipped with High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.5 ° C, supports 0-9999 minutes timing function, and has multiple Safety protection mechanisms.