Electromagnetic Magnetic Stirrer

Electromagnetic stirrers drive the rotation of magnetic stir bars inside containers through electromagnetic fields, generating vortex currents to achieve liquid mixing. They are used for stirring solutions and homogenizing reactants in laboratories, avoiding contamination from mechanical contact.
Selection
Select glass or plastic compatible models based on the container material, match the speed range according to the liquid viscosity, consider the need for heating functions, and pay attention to the compatibility between the magnetic stir bar size and the container bottom.

Terms

Standards

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Using DC three-phase brushless motor, torque up to 50mN · M, Max. stirring Capacity 10L, Speed range 50~ 1800rpm, stable operation and no electromagnetic interference.

$ 169.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, digital display Rotation speed is clear and intuitive, suitable for large-capacity stirring needs.

$ 545.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Max. stirring Capacity 1000mL, Speed range 0-1600rpm, using magnetic field drive technology implementation of non-contact stirring, suitable for a variety of low viscosity liquid mixing needs.

$ 107.00

Using brushless DC motor to achieve stepless speed regulation of 0~ 1500rpm, equipped with strong magnetic steel to ensure strong stirring force and stable Rotation speed, Temperature range RT +~ 150 ℃, Heating power 360W adjustable, support mechanical timing 20~ 120min.

$ 212.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Adopt abrasion-free magnetic coil technology, Speed range 60~ 2000rpm, support cycle swirl/spin and clockwise setting, IP65 waterproof rating, quieter and lighter operation.

$ 153.00

Rotation speed is stable with brushless DC motor, torque is 73.5mN · M, magnetic force is especially strong, suitable for large capacity stirring, Max. stirring Capacity 20L, Speed range 60~ 2000rpm.

$ 323.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, suitable for large-capacity stirring, and equipped with digital display Rotation speed.

$ 520.00

Magnetic field drive technology implementation of liquid mixing, Speed range 0-1800rpm, Max. stirring Capacity 2000ml, equipped with 0-9999 minutes timing function, table size 130 * 130mm.

$ 104.00

Brushless DC motor provides 20mN · M torque, stirring speed 100~ 2000rpm, with automatic thermostatic function, Heating power 340W, temperature control accuracy +/- 1 ℃, working plate surface black stainless steel.

$ 186.00

Magnetic field drive technology implementation of liquid mixing, Speed range 0-1800rpm adjustable, maximum stirring capacity 2000ml, equipped with digital timing function, support charging and easy to move operation.

$ 115.00

Brushless DC motor and strong magnetic steel, Max. stirring Capacity 10L, temperature control accuracy +/- 1 ℃, with automatic temperature control function and Heating power stepless adjustment.

$ 249.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.