Laboratory Thermostatic Stirrer

The laboratory constant temperature stirrer maintains the set temperature through heating elements and temperature sensors, while the motor drives the stirring paddle to rotate and mix samples. It is used for constant temperature mixing and reactions of samples such as coatings and inks, ensuring stable experimental conditions.
Selection
Select the stirring torque based on sample viscosity, and determine the stirrer size according to container dimensions. Consider temperature range and accuracy requirements, with heating options such as electric heating jackets or water baths. Pay attention to material corrosion resistance, and ensure the operation interface is user-friendly.

Terms

Standards

Instruments

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Driven by brushless DC motor, strong stirring force, Max. stirring Capacity 5L, temperature control accuracy +/- 1 ℃, suitable for thermostatic stirring occasions in various fields.

$ 249.00

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Brushless DC motor provides 20mN · M torque, stirring speed 100~ 2000rpm, with automatic thermostatic function, Heating power 340W, temperature control accuracy +/- 1 ℃, working plate surface black stainless steel.

$ 186.00

With 100~ 1300rpm stepless speed regulation function, support automatic thermostatic control, Heating power range of 20-400W, temperature control accuracy of +/- 1 ℃, Max. stirring Capacity 3L.

$ 181.00

Quadruple synchronous design, Max. stirring Capacity 1000mL, Temperature range RT + to 100 ℃, stepless speed regulation 60-2000rpm, suitable for small volume sample precision stable Stir.

$ 296.00

Support 100 ℃ thermostatic treatment, compatible with 35 1.5ml centrifuge tubes, optional 4-degree electronic ice box and intelligent thermostatic module, suitable for a variety of experimental scenarios.

$ 148.00

With two-way stirring function, commutation time 5-30 seconds adjustable, Max. stirring Capacity up to 3000mL, Heating power 360W stepless adjustable, support mechanical timing 0-120 minutes.

$ 211.00

Temperature range 5~ 60 ℃, can correct liquid temperature, avoid surface tension test error caused by temperature change, suitable for High Accuracy sample thermostatic control requirements.

$ 220.00

Heating mode heating speed, thermostatic Fluctuation +/- 0.2 ℃, equipped with double-decked door structure and independent temperature limit alarm system, to ensure the safe and stable operation of the experiment.

$ 622.00

Driven by three-phase brushless DC motor, Rotation speed 50-1500rpm can be adjusted smoothly, temperature control accuracy +/- 0.5 ℃, with soft start anti-hopper and temperature protection functions, suitable for long-term unattended operation.

$ 424.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Four-station independent operation does not interfere with each other, the brushless DC motor provides 12.5mN · M torque, temperature control accuracy of +/- 1 ℃, supports automatic temperature control function and stepless speed regulation of 0~ 1500rpm, to meet the needs of multi-sample synchronous processing.

$ 569.00

With heating and cooling functions, Temperature range -20~ 100 ℃, Fluctuation +/- 0.05~ 0.1 ℃, can be 10-stage program control, to achieve timing thermostatic, heating and cooling.

$ 1372.00

Temperature control accuracy of +/- 0.1 ℃, Temperature Fluctuation, Oscillation Frequency Range 0~ 300rpm, reciprocating oscillation mode, suitable for thermostatic fostering of fluid and solid compounds.

$ 587.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.