Micro-sample rheoMeter

Micro-sample rheometers measure the flow and deformation properties of small amounts of materials by applying shear forces. They are used in industries such as coatings and inks for formulation development and quality control, analyzing parameters like viscosity and elasticity.

Instruments

The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.

$ 683.00

The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.

$ 683.00

The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.

$ 683.00

The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The rotor shear rate is 2.0N, the sample volume is only 100 μL, the applicable viscosity range is 500~ 1000000mPa · s, the accuracy is +/- 2% F. S, suitable for processing a variety of fluid samples.

$ 683.00

Shear rate 2.0N, sample volume 1700μL, applicable viscosity range 32-63000mPa · s, accuracy +/- 2% F. S, suitable for a variety of fluid measurement.

$ 683.00

The shear rate is 13.3N, the sample volume is 24μL, the applicable viscosity range is 75~ 150000mPa · s, the measurement accuracy is +/- 2% F. S, and it is suitable for a variety of fluid tests.

$ 683.00

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

Using ARM microprocessor and German technology, the test can be completed with only 1-2ml of trace samples. With automatic heating, sweeping, ignition and printing functions, no external combustible gas is required, and the operation is simple and reliable.

$ 4269.00

Glass sensitive film of 4.5 mm and point ceramic liquid junction, suitable for micro sample measurement, Operating temperature range 0~ 80 ℃, providing stable reference potential.

$ 267.00

The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.

$ 683.00

Using electromagnetic force equilibrating Sensor technology, dual range design with the highest accuracy of 0.01mg, with micro sample weighing function, Fast Response and Stability, suitable for powder and liquid micro weighing.

$ 1393.00

Oscillation Frequency Range 300-3000rpm, Timed 5-120 minutes, Net weight only 1.2kg, suitable for micro Sample Handling, providing stable oscillation effect.

$ 133.00

With five linear heating rate control, Temperature resolution of 0.1 ℃, support capillary method and coverslip method Measurement mode, high power microscopic observation is suitable for dark, low purity and analysis samples.

$ 859.00

Articles

Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Melt Flow Indexer and Torque Rheometer in the Evaluation of Processing Properties of Thermoplastic Resins
This article introduces the differences and selection methods between melt indexers and torque rheometers in evaluating the processing properties of thermoplastic resins.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
Capillary Rheometer for Determining the Shear Viscosity Curve of Hot Melt Adhesives
This article introduces the method of measuring the shear viscosity curve of hot melt adhesives using a capillary rheometer. The principle involves pushing molten hot melt adhesive through a capillary, measuring the pressure and flow rate, and then calculating the shear stress and viscosity.
Can you distinguish between a rotational viscometer, a rheometer, and a cone-plate viscometer?
Rotational viscometers, rheometers, and cone-plate viscometers are core instruments in the field of material characterization, with significant differences in measurement principles, geometric structures, and functional positioning.