Laboratory vacuum electRode slurry mixer

The laboratory vacuum electrode slurry mixer removes bubbles through a vacuum environment and ensures uniform mixing of the electrode slurry through mechanical stirring. It is used for slurry preparation in fields such as lithium batteries and electronic components, ensuring that the materials are free of bubbles and fully dispersed.
Selection
When selecting, consider that the vacuum level meets the requirements for slurry degassing, the stirring speed matches the viscosity of the slurry, the materials are corrosion-resistant and easy to clean, the capacity is suitable for the experimental volume, and the observation window facilitates monitoring of the mixing process.

Terms

Standards

Instruments

Designed for Calcium Composite ElectRode, 250ml Standard Encasement is provided to ensure ElectRode calibrating accuracy and long-term Stability for a variety of analytical scenarios.

$ 110.00

The equipment operates under vacuum or pressure conditions, with a processing viscosity of 10000MPas, Operating temperature of 170 ° C, equipped with anchor type screw scraping wall stirring slurry and high shear homogeneous Mulser, supporting Multi-ParaMeter measurement such as material temperature and pressure.

$ 7416.00

The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.

$ 2939.00

The built-in vacuum pump realizes 0~ -80kPa Vacuum Level, the fully transparent vacuum Chamber can hold 12 samples, the program control supports 80 sets of paraMeter storage, and the vacuum cycle operation is automatically completed.

$ 4108.00

ElectRode composite design without reference ElectRode, measurement range 0.002 to 69000ppm, circular Glass sensitive film accurate sensing Ion concentration, operation temperature range 5~ 80 ° C, anti-interference ions such as silver, lithium, potassium, titanium.

$ 396.00

Vacuum chuck area of 300 * 400mm, equipped with 150W vacuum pump, aperture 0.8mm to ensure uniform adsorption, improve Spreader accuracy and Stability.

$ 638.00

The effective volume utilization rate of rectangular vacuum Chamber is high, each layer can be independently heated and vacuumed to inject nitrogen without interfering with each other, the temperature control accuracy is +/- 1 ℃, the Vacuum Level is 133Pa, and the double-decked tempered Glass door is easy to observe.

$ 7880.00

With programmed vacuum cycle control, the maximum number of cycles is 99 times, and the drying time is shortened by more than 50% compared with the traditional method; equipped with a digital vacuum Gauge, the control accuracy is +/- 1% to ensure a stable vacuum environment.

$ 3294.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level 133Pa ensures efficient handling, double-decked tempered Glass doors are easy to observe, and over-temperature protection enhances safety.

$ 4222.00

ElectRode filling solution suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, calcium ion type design to ensure measurement accuracy, prolong ElectRode life.

$ 135.00

With programmed vacuum cycle control, it can set the range of 50~ 900Pa Vacuum Level, and the drying time is shortened by more than 50%; it adopts digital vacuum Meter automatic control, accuracy +/- 1%, and supports 7 groups of 63-step temperature programming.

$ 4321.00

The composite ElectRode design does not require reference ElectRode, the Solid State Sensor can be directly immersed in liquid measurement, the measurement range is 0.04 to 39000ppm, and the epoxy resin shell is durable.

$ 396.00

Designed for Sodium Composite ElectRode, the 250ml Standard Encasement ensures calibrated Stability and provides accurate sodium concentration measurement for a variety of water quality monitoring scenarios.

$ 110.00

1Mm Vacuum aperture diameter and 18mm hole spacing design, equipped with 176 adsorption holes to ensure that the substrate is flat and fixed, with 150W vacuum pump to achieve stable adsorption effect.

$ 654.00

Using Platinum ElectRode, Glass Shell Structure, Temperature range 0-50 ℃, Dimension 12 * 120mm, BNC connector to ensure stable connection.

$ 110.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Vacuum adsorption coating machine solves the flatness challenge in the transfer of ultra-thin graphene films.
The vacuum adsorption coating machine transfers graphene films smoothly onto target substrates through controlled negative pressure, solving issues such as wrinkling, tearing, and contamination often encountered with traditional methods.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Vacuum adsorption coating machine is used for the coating of proton exchange membrane fuel cell electrodes.
This article introduces the application of vacuum adsorption coating machines in the coating of proton exchange membrane fuel cell electrodes.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Vacuum adsorption coating of perovskite precursors on flexible substrates.
This article introduces the process of vacuum adsorption coating for perovskite precursors on flexible substrates.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
Daily Maintenance and Common Troubleshooting Guide for Titrators in the Laboratory
This guide introduces the daily maintenance and common troubleshooting methods for titrators. Daily maintenance includes cleaning and sealing checks of burettes and liquid pathways, proper storage and performance verification of electrodes, as well as inspections of the instrument's external environment and mechanical components.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Application of Vacuum Heating Integrated Coating Machine in the Preparation of High-Temperature Curing Coating Samples
This article introduces the application of the vacuum heating integrated film coater in the preparation of samples for high-temperature curing coatings. The equipment reduces bubbles in the coating by creating a vacuum environment and integrates programmable heating and curing functions, enabling precise temperature control to promote the chemical cross-linking of the coating and form a uniform film.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.