Liquid AFNOR Viscosity Cup

The liquid AFNOR viscosity cup determines viscosity by measuring the time it takes for a fixed volume of liquid to flow out from a small hole at the bottom of the cup. It is suitable for the rapid testing of Newtonian fluid viscosity in industries such as coatings and inks, offering simple operation and intuitive results.
Selection
When selecting, consider matching the viscosity range of the measured liquid with the nominal range of the cup type. Choose stainless steel or brass materials based on the material characteristics. Ensure the cup mouth diameter and outflow hole specifications comply with AFNOR standards, and regularly calibrate the outflow time to guarantee measurement accuracy.

Terms

Standards

Instruments

Made of titanium anodic oxidation aluminum, the diaMeter of the flow hole is 2.5mm, and each Cup is engraved with an independent serial number, which is suitable for accurate measurement of liquid viscosity in the laboratory.

$ 438.00

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 6mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability.

$ 438.00

Made of titanium anodic oxidation aluminum, the flow hole diaMeter is 8mm, the Cup height is 75mm, and each Cup is engraved with an independent serial number to ensure Measurement accuracy and durability, suitable for liquid viscosity testing.

$ 438.00

Using titanium anodic oxidation aluminum material, flow hole diaMeter 4mm, Cup height 75mm, corrosion resistance and lightweight, each Cup engraved with an independent serial number to ensure accurate and reliable measurement.

$ 438.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

The filter diaMeter of 1-8mm can be freely replaced, the Cup mouth annular groove is designed to store overflow liquid, titanium anodic oxidation aluminum Cup body with stainless steel filter positioner, the distance between the outflow hole and the liquid level should be greater than 100mm.

$ 436.00

With double-decked anodic oxidation aluminum housing structure, temperature control is achieved by chilling down and heating liquid, suitable for a variety of standard viscosity Cups, hard anodic oxidation aluminum and stainless steel materials to ensure durability.

$ 1287.00

Replaceable 1-8mm aperture stainless steel filter, Cup mouth annular groove design to store overflow liquid, Cup body made of titanium anodic oxidation aluminum, outflow hole diaMeter 6mm, easy to clean and equipped with a unique serial number.

$ 420.00

Adopt replaceable filter design, support 1-8mm aperture selection; Cup annular groove can store overflowing liquid, Cup wall has no clean dead angle; comply with DIN53211 standard, with unique serial number for easy tracking.

$ 441.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Using anodic oxidation aluminum alloy Cup body and stainless steel nozzle, 4mm pore size design can measure 35-135cst viscosity range, and accurately evaluate material Tack through 108ml liquid outflow time.

$ 130.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.