In-line Viscosity Analyzer

Online viscometers measure the fluid flow resistance in real-time through sensors, converting rotational torque or vibration frequency into viscosity values. They are used in production processes such as coatings and inks to monitor changes in material consistency, ensuring process stability and product quality consistency.
Selection
When selecting, it is necessary to match fluid characteristics such as the shear rate range, consider the installation method and pipeline compatibility, pay attention to the corrosion resistance of the sensor material, confirm the temperature and pressure adaptation range, check the output signal and system integration capability, and evaluate the ease of maintenance and cleaning.

Terms

Standards

Instruments

Filter diaMeter 2mm, viscosity measurement range up to 60cst, flow time 35-80 seconds, stainless steel durable and easy to clean, in line with international standards to ensure Measurement accuracy

$ 521.00

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

DiaMeter 1mm outflow hole design, in line with DIN53211 standard, using stainless steel material to improve Abrasion Resistance and rust resistance performance, suitable for testing requirements of different viscosity Coatings.

$ 154.00

500Ml capacity S6 viscosity standard oil, 20 ℃ viscosity 8.911mPa · s, 25 ℃ viscosity 7.498mPa · s, traceable to national standards, compatible with a variety of test equipment calibrating requirements.

$ 472.00

Using 6mm filter diaMeter, viscosity measurement range 188-684cSt, flow time 30-100 seconds, in line with international standards design, suitable for rapid viscosity evaluation of newtonian fluids, aluminum alloy structure to ensure durability.

$ 432.00

Portable handle design without bracket, easy to carry; 4mm aperture aluminum Cup body, viscosity measurement range below 150s, in line with the national standard GB/T1723.

$ 130.00

Equipped with round water Bath cover and aluminum Cup body, flow hole diaMeter 5.6mm, capacity 50ml, in line with GB/T1723 standard, suitable for viscosity measurement.

$ 152.00

Brass material Benchtop design, flow hole diaMeter 4mm, volume 100ml, in line with GB/T1723 standard, suitable for viscosity below 150s Coating detection, correction factor 0.97~ 1.03.

$ 130.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Using titanium anodic oxidation aluminum material, filter diaMeter 6mm, viscosity measurement range 188~ 684cSt, in line with ISO2431 international standards, channel design is sensitive to outflow time, requiring special cleaning tools maintenance.

$ 465.00

Aperture 4.12mm, viscosity measurement range of 70~ 370cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Using titanium anodic oxidation aluminum material to ensure durability, 5mm filter diaMeter covers 91~ 326cSt viscosity range, in line with ISO2431 standards, short channel design is sensitive to outflow time, requiring special cleaning tools to maintain.

$ 497.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.