ISO Aluminum Viscosity Cup

The ISO aluminum viscosity cup measures the viscosity of fluids by recording the time it takes for the fluid to flow through a standardized orifice. It is used for quality control of fluids such as paints and inks, in compliance with ISO 2431 standards.
Selection
Select the corresponding aperture model based on the viscosity range of the fluid being measured, consider temperature adaptability, verify the cup dimensions with the standard certificate, and ensure the material's corrosion resistance meets the usage environment.

Terms

Standards

Instruments

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

It adopts aluminum alloy Cup body and stainless steel outflow nozzle structure, the outflow aperture is 6mm, and the outflow time of Newton-type liquid in the viscosity range of 188~ 684cSt can be measured, which meets the test requirements of international standards.

$ 146.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.

$ 151.00

Using aluminum alloy Cup body and stainless steel filter, the outflow aperture of 3mm, 4mm, 6mm optional, Measurement range of 30~ 100 seconds, in line with international general viscosity test standards.

$ 238.00

Using titanium anodic oxidation aluminum material, filter diaMeter 6mm, viscosity measurement range 188~ 684cSt, in line with ISO2431 international standards, channel design is sensitive to outflow time, requiring special cleaning tools maintenance.

$ 465.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, aperture 1.90mm, viscosity measurement range of 10~ 35cSt, flow time of 55~ 100 seconds, suitable for liquid viscosity evaluation.

$ 130.00

Using titanium anodic oxidation aluminum material to ensure durability, 4mm filter design supports 34~ 135cSt viscosity test, conforms to ISO2431 standard, provides High Accuracy and repeatability, easy cleaning and maintenance.

$ 465.00

Using aluminum alloy anodic oxidation Cup body and stainless steel nozzle, the diaMeter of the flow hole is 2.53mm, the viscosity range is 25~ 120cSt, and the liquid viscosity is evaluated by measuring the outflow time, which conforms to the ASTM standard design.

$ 130.00

Replaceable 1-8mm aperture stainless steel filter, Cup mouth annular groove design to store overflow liquid, Cup body made of titanium anodic oxidation aluminum, outflow hole diaMeter 6mm, easy to clean and equipped with a unique serial number.

$ 420.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, the aperture is 5mm, and the viscosity measurement range is 91~ 326cSt, which is suitable for the determination of Newton-type liquid outflow time.

$ 146.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article primarily discusses how to uniformly coat the positive electrode slurry onto aluminum foil in lithium-ion battery manufacturing. The slurry itself exhibits shear-thinning properties, making it suitable for coating applications.
The film coater is used for experimental-grade uniform coating of lithium-ion battery cathode slurry on aluminum foil.
This article explores the technique of uniformly coating lithium-ion battery cathode slurry on aluminum foil using a laboratory-grade coating machine.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
Tensile strength testing machine measures the tensile properties of paper.
The tensile strength tester is used to determine the tensile properties of paper by simulating the stretching process to obtain key parameters such as tensile strength and elongation at break. The testing follows standards such as ISO and GB to ensure reliable results.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Application of Whiteness Meter in the Evaluation of Paper Brightness and Visual Comfort
The whiteness meter quantifies the brightness and whiteness of paper by measuring its reflected light characteristics, following international standards such as ISO to ensure comparability of results. The brightness of paper affects visual comfort, and moderate whiteness can enhance the reading experience, but excessive whiteness may lead to fatigue.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.