Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.
Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.
Utilizing a wire-wound process, the wet film thickness is 11.4 μm, with a diaMeter of 9.5 mm and a coating width of 300 mm. The stainless steel material ensures durability and precise coating results.
Stainless steel material corrosion resistance, 100ml volume to meet the standard test requirements, easy to operate, accurate measurement of Coating density by weighing method to ensure the accuracy of quality control.
Measurement range 0~ 20mm, accuracy of 0.001mm, contact pressure 20 +/- 5kpa, suitable for sheet material thickness detection with certain tightness.
The vacuum pressure plate is made of pure bronze, the drying temperature can be adjusted from room temperature to 120 ℃, equipped with double drying stations and intelligent drainage system, and the paper uniformity can reach 96.
Equipped with a 200mm diaMeter pick-up cylinder and an 8-liter capacity, the manual Stirrer works in tandem with an 80-mesh forming filter for uniform Pulp distribution and efficient dehydrating.
Measurement range 0-20mm, accuracy 0.001mm, contact pressure 20 +/- 5kPa, suitable for paper, Cardboard and sheet material Film thickness detection, in line with a number of international standards.
The linear guide is used to ensure smooth and fast sampling, and the imported tungsten sheet is cut without burrs and durable. It supports 18mm thickness sampling, and can cut 25 × 100mm and 25 × 80mm samples.
Glass material can be used for repeatability, Checkerboard size 25x25mm, shape 250x100mm, in line with the national standard GB/T1726, durable and accurate test.
Measurement range 0~ 12.7mm, resolution up to 0.001mm, contact pressure 20 +/- 0.5Kpa to ensure measurement Stability, suitable for all kinds of sheet material thickness detection.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
Measurement range 0-20mm, resolution 0.01mm, contact pressure 20 +/- 0.5kpa to ensure Measurement accuracy, in line with a number of international standards, suitable for all kinds of sheet material thickness detection.
Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.
Measurement range 0-4mm, contact pressure 100 +/- 10kPa, contact area 200 +/- 5mm ², measurement plane parallelism ≤ 0.0005mm, suitable for a variety of sheet material thickness accurate determination.