Colloidal Coating Tester

The colloidal coating tester evenly applies colloid onto the substrate surface using a blade or roller, simulating the production coating process. This equipment allows for the adjustment of coating thickness and speed, and is used to test coating uniformity, adhesion, and drying performance. It is suitable for laboratory quality control of materials such as paper and film.
Selection
When selecting a colloidal coating tester, consider the compatibility of the coating method with production equipment, substrate compatibility and maximum coating width, thickness adjustment accuracy and speed control range, ease of operation, equipment maintenance requirements, and the manufacturer's technical support capabilities.

Terms

Standards

Instruments

Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.

$ 178.00

Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.

$ 120.00

Spreader 13 micron wet film thickness, application width up to 300mm, 304 stainless steel for durability and precise coating control.

$ 178.00

The extrusion production process ensures uniform coating, with a wet film thickness of 60μm meeting the demands of precise experiments. The 304 stainless steel material is durable and easy to clean, making it suitable for diverse coating performance tests.

$ 178.00

Using the formed pRoduction process, the wet film thickness is 6 microns, the accuracy is 0.5 microns, the cleaning is convenient and there is no worry of broken wire, to ensure the precision and durability of the coating prepative.

$ 120.00

Wound wire design, wet film thickness 125.7 microns, coating width 300 mm, stainless steel material ensures durability and precise coating effect.

$ 167.00

Using a wire-wound coating process, with a wet film thickness of 32.0 μm and a coating width of 300 mm, it is suitable for substrates prone to curling and convexity, enabling uniform wet film coating, with a wire diaMeter of 0.36 mm.

$ 167.00

Wet film thickness 29.7 microMeters, coating width 300 milliMeters, using stainless steel wire-winding process, suitable for experimental sample preparation.

$ 167.00

The punch is pushed to the test plate at a constant speed of 0.2 +/-0.1mm/s, and the thickness range of the test plate is 0.30-1. 25mm, which can detect the degree of coating cracking and is suitable for testing of various materials.

$ 1029.00

Formed design Coating Weight is about twice the wide-wound drawdown bar, wet film thickness 13μm, film accuracy of 0.5 micron, 304 stainless steel material to ensure durability.

$ 157.00

304 stainless steel material, wet film thickness 8 μ m, application width 300mm, formed pRoduction process to ensure uniform coating and continuous wire.

$ 178.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

The split structure is equipped with a dedicated thick coating Probe, Measurement range of 0~ 13000 μm, accuracy +/- 3%, IP65 Protection Rating and high-speed measurement capability of more than 60 readings per minute.

$ 1213.00

Utilizing a wire-wound process, the wet film thickness is 11.4 μm, with a diaMeter of 9.5 mm and a coating width of 300 mm. The stainless steel material ensures durability and precise coating results.

$ 167.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Articles

Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heating and blade coating of gel electrolyte films for zinc-ion batteries.
This article introduces the heating doctor-blade coating method for preparing gel electrolyte films in zinc-ion batteries. The method involves spreading a slurry onto a substrate using a doctor blade, followed by heating to evaporate the solvent and form a film.
The experimental sample of pressure-sensitive adhesive coated on the surface of PET labels using a film coater.
This article introduces the experimental method of applying pressure-sensitive adhesive to the surface of PET labels using a coating machine.
The film applicator applies hydrocolloid adhesive onto medical dressings.
The coating machine is used to apply a hydrocolloid adhesive evenly onto the substrate of medical dressings. This adhesive, made from hydrophilic polymer materials, maintains its adhesion and comfort in moist environments.
The coating machine applies the adhesive layer of the plaster patch onto the backing layer.
The coating machine applies adhesive evenly onto the backing material through steps such as feeding, coating, drying, and winding, forming a stable adhesive layer.
Effect of Spin Coater Rotation Speed and Acceleration Settings on Photoresist Coating Uniformity
This article primarily explores how the settings of rotational speed and acceleration in a spin coater affect the uniformity of photoresist coating.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
The Role of Roll-to-Roll Coating Machines in Photoresist Coating for Semiconductor Packaging
The roll-to-roll coating machine achieves efficient production through continuous unwinding, coating, and rewinding processes. It utilizes precise coating methods to control the thickness of the adhesive film and is suitable for coating materials such as flexible substrates.
The laboratory coating machine provides uniform coating for OCA optical adhesive and AR coating.
The laboratory film coater is a precision instrument used to prepare uniform thin films on substrates, playing a crucial role in the research and development of OCA optical adhesives and AR coatings. It ensures consistent film thickness and prevents defects by precisely controlling parameters such as coating speed, gap distance, and solution viscosity.