High Performance Liquid Chromatograph

High-performance liquid chromatography (HPLC) utilizes a high-pressure pump to propel the liquid mobile phase, which carries the sample through the chromatographic column. Separation is achieved based on the differences in distribution coefficients of various components between the stationary phase and the mobile phase. The detector analyzes the eluted components, enabling quantitative and qualitative detection in fields such as chemical engineering and pharmaceuticals.
Selection
When selecting, consider the polarity matching of the target analyte to choose the appropriate column type. Select a UV or fluorescence detector based on detection requirements. The sample throughput determines the configuration of the autosampler. The system pressure tolerance must meet the method requirements. Additionally, balance operational and maintenance costs with the technical support provided by the supplier.

Terms

Standards

Instruments

High-performance ceramic sand core liquid junction and silver ion trapping hydrazine structure, equipped with liquid reference system, Dimension Φ 12 × 260mm, suitable for large volume container sample detection.

$ 251.00

High-performance ceramic core liquid junction, Temperature range 0-100 ℃, Long life reference structure design, to ensure stable measurement in high temperature samples, suitable for a variety of high temperature environments.

$ 251.00

High Performance Ceramic Core Liquid Boundary and Good Lead Free Glass Material, pH Measurement range 0-14, Temperature range 0-80 ℃, suitable for RoHS compliant samples.

$ 251.00

Measurement accuracy up to 0.01pH, using high performance ceramic sand core liquid junction and silver ion trapping hydrazine structure, reference solution can be added liquid design, Temperature range 0-80 ℃, suitable for a variety of water sample environment.

$ 194.00

Using 1200L/mm high performance grating and C-T monochromator structure, equipped with imported tungsten lamp and high Sensitivity photoelectric converter, Light spectrum Bandwidth 4nm, Wavelength range 340~ 1000nm, to ensure high resolution, low stray light and stability testing performance.

$ 412.00

With a fully automatic liquid inlet device, the liquid inlet accuracy reaches 0.001 μL, equipped with SONY high-speed industrial-grade chip and a variety of Measuring methods, it can accurately measure 0-180 ° contact angle and 0-3000mN/m surface tension to meet various material surface performance analysis requirements.

$ 5495.00

Measurement accuracy of 0.01pH and Temperature range of 0-60 ℃ is achieved by adopting high performance ceramic sand core liquid interface and additive liquid reference structure.

$ 251.00

Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.

$ 3331.00

Suitable for laboratory sampling test, high corrosion resistance, can measure a variety of material density, with sampling test type for liquid special anti-corrosion accessories.

$ 123.00

Using high performance MCS-51 single chip microprocessor control, weighing range 0~ 1000g, readability accuracy 1mg, with automatic correction, integration time adjustable and a variety of weighing functions.

$ 638.00

Using 1200L/mm high-performance grating and imported photoelectric converter, stray light is as low as 0.03% T, wavelength Precision +/- 0.5nm, wide sample Chamber can expand 10cm sample holder, support automatic wavelength correction and Illuminant switching.

$ 1848.00

Using high-performance MCS-51 single chip microprocessor control, weighing range 0~ 220g, readability accuracy 0.1mg, with RS232C standard output interface and automatic correction function to ensure high weighing results Accuracy.

$ 412.00

The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.

$ 875.00

Suitable for solid-state semi-solid piercing measurement, using high-performance ceramic core liquid junction and long-life reference structure, Measurement range 0-14pH, Temperature range 0-60 ℃.

$ 251.00

DC three-phase brushless motor, no spark and high efficiency, large torque, motor temperature rise is extremely small, Speed range 60~ 1500rpm, can adapt to high viscosity liquid stirring, stable and reliable operation.

$ 399.00