DIN immersion viscosity Cup

DIN immersion viscosity cups measure viscosity by calculating the time it takes for a fluid to completely drain through a small hole at the bottom of the cup. They are used for quality control of fluids such as coatings and inks. During operation, the cup is immersed into the sample, and the outflow time is recorded and converted into a viscosity value.
Selection
When selecting, consider the viscosity range of the fluid being tested and match it with the corresponding cup number based on the aperture size. Pay attention to material compatibility; for corrosive fluids, choose stainless steel cups. Determine the cup type according to the DIN 53211 standard, and account for environmental temperature effects by applying calibration corrections.

Terms

Standards

Instruments

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Made of stainless steel, the flow hole diaMeter is 2mm, according to DIN 53211, providing accurate viscosity measurement for Newtonian or near newtonian fluids.

$ 581.00

One-handed operation design is convenient for immersion measurement, 4mm filter diaMeter corresponds to 25-150 seconds outflow time, titanium anodic oxidation aluminum material ensures durability, temperature fluctuations need to be controlled within +/- 0.2 ℃ to ensure Precision.

$ 375.00

Designed for easy immersion measurement with one hand operation, the 8mm filter diaMeter covers a specific viscosity range, and the aluminum alloy and stainless steel construction ensures durability and accurate flow time determination.

$ 388.00

Using aluminum alloy material, filter diaMeter 4mm, viscosity measurement range 34-135cSt, in line with international standards design, hand-held immersion operation is simple, suitable for laboratory accurate measurement.

$ 432.00

Measurement range covers common Coating viscosities with 3mm filter diaMeter, immersion design supports one-handed operation, aluminum alloy ensures durability and meets DIN 53211 requirements.

$ 381.00

Immersion design, 2mm outflow aperture, viscosity measurement range 5~ 60cSt, stainless steel material, ASTM D4212 standard, correction factor 0.95~ 1.05.

$ 135.00

Aperture 4.26mm, viscosity measurement range 200~ 1200cSt, stainless steel corrosion resistance, portable immersion design for easy operation, correction factor 0.95~ 1.05 to ensure accuracy.

$ 131.00

Measurement range 400-1800cSt, equipped with 44ml Cup volume, correction factor 0.95-1, accurate viscosity test at 25 ℃ thermostatic environment.

$ 131.00

Using aluminum alloy and stainless steel material, filter diaMeter 5mm, capacity 100ml, one-handed operation design for easy immersion Coating measurement, Precision high and in line with industry standards.

$ 386.00

Made of titanium anodic oxidation aluminum and stainless steel, the flow hole diaMeter is 6mm, the capacity is 100ml, and the one-hand immersion measurement meets the DIN 53211 standard to ensure High Accuracy Viscosity Testing.

$ 381.00

Made of stainless steel, the diaMeter of the flow hole is 5mm, the Cup height is 74mm, and the viscosity is calculated by measuring the liquid outflow time, which meets international standards and has a unique serial number.

$ 559.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

Made of aluminum alloy and stainless steel, equipped with 2mm filter diaMeter, one-handed operation design for easy immersion Coating measurement, Flow Time Measurement range 25-150 seconds, Precision and easy maintenance.

$ 382.00

3Mm stainless steel filter design, viscosity measurement range of 7-42cst, flow time of 30-100 seconds, in line with international standards dimensional tolerance, equipped with a unique serial number to ensure measurement accuracy.

$ 436.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.