Made of titanium and aluminum, equipped with stainless steel cutters and LED lighting Microscope, Measurement range 20-2000μm, unique swirl/spin system includes multiple cutters for precise measurement of Coating thickness and evaluation of substrate defects.
In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.
Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.
Using hexagonal aluminum alloy structure, Measurement range 25~ 3000um, Division 25~ 200um, Coating thickness can be measured immediately after construction, in line with GB/T1764 and other standards.
In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.
Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.
The gap height is adjustable from 0 to 3000μm, the minimum scale is 5μm, and the aluminum alloy material can be completely disassembled and cleaned by anode treatment. It is suitable for Drawdown Vacuum Plate, Glass plate and other solid substrate film preparations.
Probe surface with wear-resistant aluminum alloy, braided cable to adapt to high temperature rough surface, resolution up to 0.1 μm, support split remote measurement, can store 2500 readings.
Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.
Measurable Film thickness 0.4-8 mm, accuracy 0.5HW, mechanical compression spring design durable, high toughness table glass anti-Impact, support a variety of Hardness value conversion, suitable for soft metals such as aluminum alloy.
Mechanical design for measurement on any surface, using hardened stainless steel, measurement disc diaMeter 50mm, thickness 11mm, equipped with aluminum free swirl/spin rollers, reading accuracy +/- 2μm.
The wet film thickness can be adjusted in increments of 10 μm from 2 μm, the maximum application width is 300mm, and the precision wear-resistant stainless steel blade and anodic oxidation aluminum frame are used.
The eddy Current principle is used for measurement of nonconductive coatings on non-ferrous metal substrates, with a thickness range of 0~ 625μm and an error of +/- 3%. It has IP65 Protection Rating and fast measurement capabilities of more than 60 readings per minute.
The stainless steel material is durable, the range is 10~ 100μm Division 10μm, the unilateral design is convenient for vertical pressing into the wet-film measurement, and the number of teeth 10 can accurately read the thickness value between the infiltrated and uninfiltrated teeth.
The wet film thickness can be adjusted in 10 μm increments from 2 μm, the maximum application width is 75mm, and the precision wear-resistant stainless steel blade and anodic oxidation aluminum frame meet the ASTM D823 standard.