Oxidation Damp Heat Test Chamber

The oxidation damp heat test chamber simulates high temperature and high humidity environments through its heating and humidification system, combined with oxygen supply to accelerate the oxidation process of materials. It is used to test the aging resistance of materials such as coatings and plastics in damp heat and oxygen-rich environments, evaluating their discoloration, embrittlement, strength changes, and other conditions.
Selection
When selecting, pay attention to the temperature range, which is typically 40-85℃, and the humidity range of over 95%. The inner chamber should be made of stainless steel. Determine the volume based on the sample size and ensure it has oxygen concentration adjustment functionality. Note the anti-condensation design of the observation window and the convenience of the drainage system, and ensure compatibility with the laboratory's power supply conditions.

Terms

Standards

Instruments

With inert gas protection system to prevent oxidation and decarburization of heating workpiece, rated temperature 1200 ℃, Inner Chamber dimensions 300 * 200 * 120mm, suitable for a variety of high temperature heat treatment applications.

$ 659.00

The equipment is equipped with an inlet and outlet device, which can pass inert gas to achieve anti-oxidation decarburization at a high temperature of 1000 ° C. Inner Chamber dimensions are 400 * 250 * 160mm, suitable for high temperature sintering and quenching and other heat treatment applications.

$ 691.00

With inert gas protection function, it can prevent high temperature heating workpiece oxidation decarburization, rated temperature 1000 ℃, Inner Chamber dimensions 200 * 120 * 80mm, shell made of cold plate and steel and high temperature spray.

$ 507.00

The cuboid studio improves the volume utilization rate, and the drying time is reduced by more than 40% compared with the traditional Vacuum Chamber; the stainless steel 316 material is used, the Vacuum Level is 133Pa, and the double-decked Glass door is easy to observe and can be filled with inert gas to prevent oxidation.

$ 1000.00

Adopting a specific process equipped with air inlet and outlet device, inert gas can be intRoduced to achieve high temperature heating and oxidation prevention, Inner Chamber dimensions 500 * 300 * 200mm, rated temperature up to 1000 ℃, the shell is made of cold plate and section steel and sprayed at high temperature.

$ 877.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation. Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and timing function, mirror stainless steel liner is easy to clean.

$ 480.00

Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.

$ 438.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation; Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃; with over-temperature alarm, leakage protection and timing functions, mirror stainless steel liner is easy to clean.

$ 749.00

Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation. Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, timing function and RS-485 communication interface, mirror stainless steel liner is easy to clean.

$ 622.00

Provide oxidation pretreatment function, calibrated value at 25 ° C for ORP ElectRode, 500mL large capacity design, with tamper-proof sealing to ensure the freshness and Stability of the standard liquid.

$ 141.00

Using high temperature dry heat technology to destroy microbial cell protoplasm through oxidation, Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm, RS-485 interface and mirror stainless steel liner to ensure disinfection effect and equipment durability.

$ 1098.00

With inert gas protection system can prevent high temperature heating workpiece oxidation decarburization, rated temperature up to 1200 ℃, Furnace size 200 * 120 * 80mm, the shell is made of cold plate and steel and high temperature spray.

$ 588.00

Cuboid Studio improves space utilization, drying time is shortened by more than 40% compared with traditional equipment; temperature control accuracy +/- 1 ℃, supports inert gas environment operation to avoid sample oxidation, Vacuum Level 133Pa.

$ 975.00

With inert gas protection system, effectively prevent high temperature heating workpiece oxidation decarburization; maximum temperature 1000 ℃, Furnace size 300 * 200 * 120mm; shell made of cold plate and steel, with air intake and air outlet device on the back.

$ 541.00

The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.

$ 2939.00

Articles

Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
High Performance Liquid Chromatography for the Detection of Additives in Ink
This article introduces the use of high-performance liquid chromatography (HPLC) to detect additives in ink. Additives such as photoinitiators and antioxidants affect the performance and safety of ink, making accurate detection crucial.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.
Coating Process of Transparent Conductive Oxide Thin Films and Practice of Coating Machines
This article introduces the coating process and practice of coating machines for transparent conductive oxide films. Transparent conductive oxide films possess both transparency and conductivity, making them widely applicable in fields such as touch panels and solar cells.