A visible spectrophotometer analyzes concentration by measuring the absorbance of a sample, based on the absorption characteristics of substances to visible light at specific wavelengths. It is commonly used for quantitative detection of solution components in fields such as environmental monitoring and food inspection.
Selection
When selecting, consider the measurement wavelength range to cover the requirements, match the cuvette material to the sample type, and ensure the instrument's precision meets the detection error standards. Pay attention to baseline stability and stray light indicators, and ensure the operation interface aligns with usage habits.

Terms

Standards

Instruments

Measurement accuracy better than +/- 2% with high definition color screen progress bar, data locking and real-time dynamic Adjustment.

$ 149.00

Simultaneous measurement of infrared, ultraviolet blocking rate and visible light transmittance, resolution up to 0.1%, accuracy better than +/- 2%. Using high definition color screen progress bar visual display, with data locking and real-time dynamic Adjustment to ensure accurate measurement.

$ 122.00

It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.

$ 170.00

The instrument adopts ultra-small portable design, equipped with protective rubber sleeve to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data; with D65 visible light, 940NM infrared and 350NM ultraviolet three Illuminants, Repeatability of 0.2%.

$ 751.00

Adopting non-vacuum design, equipped with Mo target and electric refrigeration detector, with seven kinds of light path automatic switching and multiple radiation protection, to ensure efficient and safe testing.

$ 15887.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 330~ 1000nm, High Linear and Stability, Support a variety of Measurement modes.

$ 364.00

Single beam of light grating system, Wavelength range 340~ 1000nm, Light spectrum Bandwidth 4nm, sealing grating monochromator design to improve Stability and Metering accuracy, automatic adjustment 0% and 100% function to simplify operation.

$ 270.00

Using 1200L/mm grating and C-T monochromator structure, stray light ≤ 0.05% T, wavelength Precision +/- 1nm, support automatic wavelength correction and wide range measurement to ensure stable and reliable data.

$ 800.00

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

Split design supports two test modes, Measurement accuracy +/- 2%, resolution 0.10%, equipped with 2.3 inch color screen and 2000 sets of Data storage functions, to adapt to the field rapid measurement needs.

$ 590.00

Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.

$ 361.00

Adopt Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can accommodate 5~ 100mm Cuvette, support a variety of Basis Weight test methods.

$ 1009.00

Using 1200L/mm grating and C-T monochromator structure, Light spectrum Bandwidth 4nm, Wavelength range 325~ 1000nm, to ensure High Accuracy Testing and Stability, wide sample Chamber supports 100mm sample holder.

$ 356.00

Support ultraviolet-visible infrared three-light transmitance measurement, accuracy of +/- 2%, single continuous Measurement mode, thickness measurement capacity of 10mm, portable design weighing only 120g for easy on-site use.

$ 365.00

With 0-100% measurement range and 0.1 resolution, accuracy +/- 2%, support ultraviolet-visible infrared three-band light transmitance measurement, swirl/spin Sensor for multi-angle testing, portable design for easy field use.

$ 385.00

Articles

UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.