Plating Thickness Gauge for Stainless Steel Plates

The stainless steel plate coating thickness gauge operates based on the principles of magnetic induction or eddy currents. The probe contacts the coating, generating changes in the magnetic field to measure the thickness of non-magnetic coatings on stainless steel substrates. It is used to detect the thickness of galvanized or chromium-plated layers on the surfaces of household appliances and kitchenware, ensuring uniform coating.
Selection
When selecting, consider the compatibility of the substrate type and coating material with the measurement principle. Check whether the measurement range and accuracy meet the process requirements. Confirm that the probe size is suitable for the workpiece shape. Verify the instrument's calibration certificate and environmental adaptability. Evaluate the ease of operation and data output functionality.

Terms

Instruments

The wet film thickness can be as low as 1.5 μm, the groove bottom is wider to provide greater Coating Weight, the chrome plating surface and extrusion process ensure durability and easy cleaning, avoiding the problem of traditional steel wire loosening.

$ 477.00

The formed pRoduction process ensures stable structure, wet film thickness can be controlled to 100μm, chrome plating surface preparation improves Abrasion Resistance and ease of cleaning, and the effective application width reaches 500mm.

$ 231.00

Range 20-370 microns, accuracy 10 microns, stainless steel corrosion resistance, hexagonal design with 24 scales, suitable for different Coating thickness measurement.

$ 231.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.

$ 119.00

Lame plating movement rate 1-300mm/s, accuracy +/- 1%, support maximum 600 * 300mm substrate, can spray thickness 0.01~ 13mm, with 1L stainless steel pressure bucket, 5 inch touch screen control, energy consumption is only 100W.

$ 3623.00

The wet film thickness can be controlled to 1.5μm, the bottom of the groove is wider and the Coating Weight is larger, and the 304 stainless steel material and chrome-plated surface are used, which is durable and easy to clean, and avoids the problem of loose and broken wires.

$ 477.00

Made of precision stainless steel, with a range of 50 to 950 μm, the 10-step tooth design can accurately measure wet film thickness, ensure painting mass and avoid material waste.

$ 109.00

Made of precision stainless steel, durable and repeatability; range 250-700 μm, Division 50 μm; in line with international measurement standards to ensure accurate painting thickness control.

$ 109.00

Using extrusion process and chrome plating surface, the minimum wet film thickness is 1.5 μm, the groove design is wide and not easy to block, and the length and shape can be freely customized to improve the uniformity and durability of Spreader.

$ 477.00

Made of titanium and aluminum, equipped with stainless steel cutters and LED lighting Microscope, Measurement range 20-2000μm, unique swirl/spin system includes multiple cutters for precise measurement of Coating thickness and evaluation of substrate defects.

$ 296.00

Measurement range of 5-500μm with a three-blade design, LED Illumination Microscope and swirl/spin system for accurate assessment of Coating thickness and substrate defects.

$ 296.00

The stainless steel material is durable, the range is 10~ 100μm Division 10μm, the unilateral design is convenient for vertical pressing into the wet-film measurement, and the number of teeth 10 can accurately read the thickness value between the infiltrated and uninfiltrated teeth.

$ 109.00

Adopt roller design, range 0-150μm, stainless steel material is sturdy and durable, in line with GB/T1764-79 and other execution standards, suitable for on-site rapid measurement.

$ 138.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.