High-temperature dryer

The high-temperature dryer uses a heating device to evaporate moisture inside the material, combined with a fan to exhaust the humid air, achieving rapid dehydration. It is used for drying materials such as coatings and plastics, and is suitable for laboratory sample drying and industrial production.
Selection
When selecting, consider the thermal resistance of materials to match the heating range, determine capacity specifications based on production output, choose between electric or gas heating methods according to site conditions, and pay attention to temperature uniformity and energy consumption performance.

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises quickly, the maximum operating temperature is 380 ° C and supports continuous work, and the hemispherical design is not easy to bruise Glass ware.

$ 222.00

Inlet and outlet devices are used to intRoduce inert gas to effectively prevent oxidation and decarburization of high-temperature heating workpieces. The Furnace volume is 16L and the maximum temperature is 1200 ° C. The high-temperature spraying process of the shell is durable.

$ 954.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Pure oil-free design ensures clean gas, exhaust volume of 1500L/min, automatic start and stop to reduce energy consumption, pressure dew point 2-10 ℃, suitable for a variety of industry needs.

$ 766.00

Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.

$ 1114.00

Adopting high-temperature non-alkali fiberglass insulation layer sealing resistance wire, the heating area is large and the temperature rises rapidly, the maximum operating temperature is 380 ℃, the hemispherical inner thermal design avoids bumping Glass ware, and supports Continuous Operating Mode.

$ 206.00

The integrated adsorption structure is used with a silent oil-free air Compressor, which can reduce the dewpoint temperature by 20~ 40 ° C, has the function of drying and sterilization, and the water outlet effect is stable and reliable.

$ 703.00

It supports high-temperature treatment at 100 ° C and can simultaneously accommodate 32 0.2ml and 25 1.5ml centrifuge tubes with accurate temperature control, making it suitable for high-throughput experiments with multiple samples.

$ 148.00

The use of high-temperature non-alkali fiberglass insulation material wOven into a hemispherical internal thermal structure, heating area and heating fast, the highest temperature 380 ℃ and support continuous work, no open flame design to avoid bumping Glass ware.

$ 119.00

Equipped with high temperature dual module, support 0.2ml * 96 hole specification, provide stable high temperature environment, suitable for multi-sample batch processing, easy and efficient operation.

$ 220.00

The use of high-temperature non-alkali fiberglass insulation layer wOven into a hemispherical internal heating heater, heating area and heating up quickly, the highest temperature of 380 ℃, no open flame design to avoid bruising Glass ware.

$ 131.00

Cold trap temperature up to -70 ℃, Ultimate vacuum degree ≤ 2Pa, equipped with 7-inch Touchscreen display operating paraMeters, support data export and remote control functions, with one-button defrosting and vacuum alarm system.

$ 8142.00

High-performance ceramic core liquid junction, Temperature range 0-100 ℃, Long life reference structure design, to ensure stable measurement in high temperature samples, suitable for a variety of high temperature environments.

$ 251.00

Can work at room temperature to 300 ℃ range, using high temperature centrifugal jet circulation pump, head up to 5 Meters, equipped with PID automatic temperature control, digital resolution 0.01 ℃, Temperature Fluctuation +/- 0.05 ℃, domestic circulation system to achieve a high degree of uniform temperature field.

$ 914.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.