VOC Leakage Detector

VOC leak detectors measure the concentration of volatile organic compounds in the air using catalytic combustion or photoionization sensors. These instruments are used in places such as chemical plants and printing workshops to monitor real-time micro gas leaks at pipeline connections and valves, ensuring a safe working environment.
Selection
When selecting, ensure the gas detection type matches the instrument's range, and the explosion-proof rating is suitable for the on-site environment. Consider response time, recovery time, sensor lifespan, and calibration intervals. Portable devices are suitable for inspections, while fixed installations are used for continuous monitoring.

Terms

Standards

Instruments

It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.

$ 189.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and linkage control.

$ 332.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; with flameproof structure and a variety of signal output, support remote monitoring and customized range, through a number of international safety certifications.

$ 332.00

Using PID Sensor technology, range 0~ 500ppm, resolution 0.1ppm, support 1-6 Sensor expansion, with a variety of signal output modes, including 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for harsh environments.

$ 1818.00

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch high definition display, supports 1-6 Sensor configurations, with 4-20mA, RS485 and other signal output, Protection Rating up to IP65, Response Time ≤ 20 seconds.

$ 545.00

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

Adopt PID light ion detection principle, range 0-50ppm, Response Time ≤ 30S, with explosion-proof structure, multiple signal output and remote alarm function, support customized wireless transmission.

$ 1171.00

Adopt PID photoion detection principle, range 0-50ppm, Response Time ≤ 30S, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote monitoring capability.

$ 1171.00

Pump-suction sampling and PID Photoion Sensor technology, Response Time ≤ 20 seconds, resolution of 0.001 ppm, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 2557.00

Using ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³, equipped with independent variable frequency wind speed adjustment device, Modular design is easy to maintain, and the operating power is as low as 1.2kw.

$ 25602.00

Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using platinum ElectRode high temperature corrosion resistance, drop height 30-40mm adjustable, time interval 30 +/- 1 seconds, automatically cut off the unqualified current.

$ 1542.00

Equipped with 2.4-inch high definition color screen, supports 1-6 Sensor expansion, with 4-20mA and RS485 output, Response Time ≤ 20 seconds, Protection Rating IP65, suitable for harsh industrial environments.

$ 583.00

Adopt ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³; equipped with independent variable frequency wind speed adjustment device, the wind speed range is 0.1-1 m/s; Modular design is easy to maintain, and the integrated gas supply purification system is easy to operate.

$ 35348.00

Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using rectangular platinum plating ElectRode, drop time interval of 30 +/- 1 seconds, with automatic cut-off protection function.

$ 1848.00

Articles

Sealing tester measures the pressure resistance and leakage of composite film bags.
This article introduces how to use a seal tester to evaluate the pressure resistance and leakage performance of composite film bags. The test primarily involves applying controlled pressure inside the packaging and observing pressure changes or leakage to assess the quality of the seal.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sealing Tester Measures Leak Points in Flexible Packaging Bags.
This article introduces how a seal tester detects air leak points in flexible packaging bags. It primarily identifies leaks through changes in pressure or vacuum, and the operation involves preparing samples, setting parameters, and conducting standardized testing.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Negative Pressure Method Sealing Tester for Detecting Leakage in Food Packaging
The negative pressure method seal tester creates a pressure difference inside and outside the packaging by evacuating air to detect leaks in food packaging. If there is a leak in the packaging, water will enter the packaging or produce continuous bubbles under the pressure difference, thereby determining the seal integrity. The test requires controlling parameters such as vacuum level and time, and should be conducted in accordance with relevant standards.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.