ISO immersion Cup

The ISO cup is a device used to measure the viscosity of liquids by recording the time it takes for a standard volume of liquid to flow out through a small hole at the bottom of the cup. It is employed in quality control for industries such as coatings and inks to ensure that the flow properties of products meet established standards.
Selection
When selecting an ISO viscosity cup, consider the viscosity range of the liquid being tested and match it with the appropriate aperture size of the cup. Choose durable materials such as stainless steel based on the frequency of use. Verify the validity of the cup's calibration certificate and inspect the outflow orifice for any wear or deformation.

Terms

Standards

Instruments

Using aluminum alloy material, filter diaMeter 4mm, viscosity measurement range 34-135cSt, in line with international standards design, hand-held immersion operation is simple, suitable for laboratory accurate measurement.

$ 432.00

Using 4mm stainless steel nozzle design, Measurement accuracy up to 34~ 135cSt viscosity range, anti-oxidation material to ensure long-term stable use, Handheld structure for easy operation.

$ 580.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.

$ 151.00

3Mm stainless steel filter design, viscosity measurement range of 7-42cst, flow time of 30-100 seconds, in line with international standards dimensional tolerance, equipped with a unique serial number to ensure measurement accuracy.

$ 436.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Using 5mm filter diaMeter, viscosity measurement range 91-326cSt, flow time 30-100 seconds, aluminum alloy material structure is strong, in line with international standards.

$ 427.00

The stainless steel material is resistant to oxidation and durable, the filter diaMeter is 4mm, and the measurement flow time is 30 to 100 seconds. It is suitable for various liquid viscosity tests and can be converted to obtain dynamic viscosity values.

$ 580.00

Immersion design, 2mm outflow aperture, viscosity measurement range 5~ 60cSt, stainless steel material, ASTM D4212 standard, correction factor 0.95~ 1.05.

$ 135.00

Designed for easy immersion measurement with one hand operation, the 8mm filter diaMeter covers a specific viscosity range, and the aluminum alloy and stainless steel construction ensures durability and accurate flow time determination.

$ 388.00

Aperture 4.26mm, viscosity measurement range 200~ 1200cSt, stainless steel corrosion resistance, portable immersion design for easy operation, correction factor 0.95~ 1.05 to ensure accuracy.

$ 131.00

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Measurement range covers common Coating viscosities with 3mm filter diaMeter, immersion design supports one-handed operation, aluminum alloy ensures durability and meets DIN 53211 requirements.

$ 381.00

One-handed operation design is convenient for immersion measurement, 4mm filter diaMeter corresponds to 25-150 seconds outflow time, titanium anodic oxidation aluminum material ensures durability, temperature fluctuations need to be controlled within +/- 0.2 ℃ to ensure Precision.

$ 375.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Short Span Compression Strength (SCT) Tester for Analyzing Paper Compression Resistance
The short-span compressive strength (SCT) tester is used to measure the resistance of materials such as paper and cardboard to compression over a short distance, primarily following international standards such as ISO 9895.
Tensile strength testing machine measures the tensile properties of paper.
The tensile strength tester is used to determine the tensile properties of paper by simulating the stretching process to obtain key parameters such as tensile strength and elongation at break. The testing follows standards such as ISO and GB to ensure reliable results.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.