Optical Chromatic Aberration Meter

An optical colorimeter calculates the color difference from a standard sample by measuring the tristimulus values of light reflected or transmitted by an object. It is used in industries such as coatings and plastics to monitor product color consistency and ensure stable production quality.
Selection
When selecting an optical colorimeter, considerations should include matching the measurement aperture to the sample size, ensuring the instrument's repeatability meets precision requirements, verifying the observation light source aligns with actual usage conditions, confirming data interface compatibility with existing systems, and ensuring the operational process suits the personnel's skill level.

Terms

Standards

Instruments

Using diffuse transmission optical path design, optical density Measurement range 0.00-6 OD, light transmitance accuracy +/- 2%, can simultaneously measure light transmitance, absolute optical density, relative optical density and Dot area ratio.

$ 673.00

Width 2cm, optical path 10mm, dimensions 12.5 × 22.5 × 45mm, specially designed for Spectrophotometer matching Cuvette, to ensure Optical inspection detection accuracy.

$ 101.00

The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.

$ 106.00

The 45/0 circular illumination geometry is used, and it is equipped with a dual measurement aperture of Φ 8mm and Φ 4mm. The chromatic value repeability is within Delta E * ab 0.03, and it supports the measurement of fluorescent samples and the calculation of various color difference formulas.

$ 4237.00

Using 45/0 geometrical optics structure, equipped with 256 pixel dual array CMOS Detector, chromatic value repeability Delta E * ab 0.05, supports a variety of color difference formula and Color index measurement.

$ 2784.00

The width is 5cm, the optical path is 10mm, and the dimensions are 12.5 × 52.5 × 45mm, which is suitable for the use of Spectrophotometer to ensure Optical inspection detection accuracy.

$ 114.00

Using photoelectric detection and microcomputer servo system, high Sensitivity, minimum reading +/- 0.005 °, Repeatability ≤ 0.007 °, low optical rotation samples with measurable transmittance ≥ 10%, no reading error.

$ 1098.00

The three-in-one optical path design can simultaneously measure the transmittance of blue light at 430nm, purple light at 395nm and visible light, and the test aperture Φ 1mm is suitable for large thickness materials. Real-time dynamic self-Adjustment ensures accurate data.

$ 373.00

Optical inspection fluorescence method without reference solution, built-in temperature sensor to calibrate data in real time, dual range design covering 0~ 20mg/L and 0~ 200% Saturation, 10 Meters long cable to support deep water or remote installation, polyformaldehyde and stainless steel composite structure to enhance environmental adaptability.

$ 636.00

Measurement principle of diffuse transmission, optical density Measurement range of 6.000 OD, accuracy +/- 0.02 OD, equipped with fixed seat and bracket, support two Measurement mode, suitable for translucent material testing.

$ 743.00

Compact and easy to carry, resolution up to 0.01, Repeatability ≤ 0.02. Adopts dual light path design, supports three Standard light sources and multiple measurement calibers, and data can be stored in the cloud through the mobile phone Mini Program.

$ 719.00

Using D/0 geometrical optics structure and full light spectrum LED Illuminant, covering 360-780nm wavelength, Repeatability chromatic value within 0.015, support multi-element Illuminant simulation and rich chroma indicators to ensure measurement Stability and accuracy.

$ 3785.00

Optical inspection system with infinity, 40X-1000X magnification range and N.A.1.25 Abbe condenser, support digitalization observation and a variety of auxiliary equipment expansion.

$ 2060.00

Infinity Optical inspection system, support a variety of Observation methods, equipped with six-hole objective lens converter and N.A.1.1 Abbe condenser, magnification 40X-1000X, easy and flexible operation.

$ 10449.00

Measurement range of +/- 89 ° optical rotation, support for optical rotation, specific rotation, concentration and sugar measurement, Precision +/- 0.01 °, Repeatability Standard Deviation 0.002 °, automatic operation is easy to integrate.

$ 3898.00

Articles

Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Transmittance Tester Measures the Clarity of Optical Films
This article introduces how to use a transmittance tester to measure the clarity of optical films. Clarity refers to the fidelity of imaging after light passes through the film. The tester is based on the principle of light transmission, calculating the clarity value using a formula by measuring the intensity of parallel transmitted light and scattered light.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
Multilayer functional films are constructed by layer-by-layer coating using a coating machine.
This article introduces a method for preparing multilayer functional films using a coating mechanism. By sequentially coating different materials layer by layer, it enables precise control over the thickness and structure of each layer, thereby adjusting the optical, electrical, and other properties of the films.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Haze meter for detecting haze and light transmittance of optical-grade resin
This article introduces the basic concepts, measurement principles, and practical applications of haze and light transmittance in optical-grade resin materials.
Haze meter detects the transparent scattering characteristics of optical coatings.
This article introduces how a haze meter detects the transparency and scattering characteristics of optical coatings. Optical coatings are used in fields such as displays and packaging, where their transparency and scattered light can affect product performance.
Paper Whiteness Tester Measures CIE Whiteness
This article explains how a paper whiteness meter measures CIE whiteness. Whiteness is a crucial optical indicator for evaluating paper quality. Traditional methods rely on subjective judgment, while modern instruments provide objective data by simulating standard lighting conditions.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Coating Distinctness of Image (DOI) Meter Evaluates Surface Imaging Clarity
The Coating Distinctness of Image (DOI) meter is an optical instrument used for quantifying the imaging clarity of coating surfaces. It analyzes the reflection of standard patterns on the coating, measuring the ratio of specular reflection to diffuse reflection to obtain an objective DOI value.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.