The single-arm double-column structure is used to realize the free drop of the face corner, and the height tracking system is equipped to make the drop height error not exceed 2%. The buffer device improves the service life and safety of the equipment.
The single-arm double-column structure is equipped with an electric lifting device, with a drop height range of 300-1500mm, a test load of 0-80kg, and a buffer device to improve service life and stability. The height error does not exceed 2%.
Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.
Using a sink structure, the maximum aperture of 12 cm, four circles per hole cover, heating tube placed in water to achieve rapid heating, Temperature range RT + to 100 ℃, temperature fluctuation +/- 1 ℃, Total Power 900W.
Tank volume 18L, Temperature range RT +~ 100 ℃, with magnetic Stir function, six-hole single row design can simultaneously process multiple samples, improve experimental efficiency.
Adopting double column guide and hydraulic buffer system, the drop height range can be set from 0 to 2000mm, the maximum load is 300kg, and it supports all-round drop testing of edge angles and has upper and lower induction protection devices.
Adopt Full Digital Control Frequency AC Motor, Speed accuracy +/- 0.5%, Effective Travel 850mm, High Accuracy Double Roller Screw and Guide Column, Support Tensile, Compression, Tension and other test modes.
Made of stainless steel, high temperature and corrosion resistance, high temperature control accuracy, equipped with double hole design, total power 600W, Tank volume 6L, to meet a variety of experimental needs.
The stainless steel material is resistant to high temperature and corrosion, the intelligent integrated circuit has high temperature control accuracy, the six-hole double row design improves the experimental efficiency, and the Tank volume is 18L to meet various needs.
The mechanical structure of double lead screw and double guide column is adopted, the force value range is 5~ 5000N, the accuracy is +/- 1%, and it has various test modes of strength, ring pressure and stacking, and supports automatic data processing and fault diagnosis.
Double station independent temperature control design, stirring speed up to 2600rpm, temperature control accuracy +/- 1 ℃, with PID self-tuning function, support dry burning, oil Bath and water Bath three Heating mode.
With four test modes and automatic programming function, the maximum Measured value 1000N, speed range 10-800mm/min, equipped with limit protection and force holding function, support pull and break stop and set force value round-trip movement.
Temperature control accuracy of +/- 0.5 ℃, Temperature resolution of 0.1 ℃, with over-temperature sound and light alarm function, stainless steel liner can adapt to different beaker sizes, support internal and external circulation, ensure sample safety and stability.
Adopt double column structure to ensure stability, rated load up to 5000N, test speed range 1-240mm/min, with stepless speed regulation and manual automatic switching function, support Force Gauge and software data collection.
The 24-hole design is compatible with the testtube with a diaMeter of less than 12mm, the maximum Operating temperature is 100 ° C, and the electronic ice box and intelligent thermostatic metal Bath module are optional to meet different temperature requirements.