Copper viscoMeter Cup

A copper viscosity cup calculates viscosity by measuring the time it takes for a fluid to flow out of a small hole at the bottom of the cup. The fluid flow time is proportional to its viscosity, making it suitable for on-site rapid testing of liquid materials such as paints and inks. It is easy to operate and ideal for routine monitoring in production sites and laboratories.
Selection
When selecting a copper viscosity cup, it is essential to consider the viscosity range of the fluid to be measured and match it with the corresponding aperture model. Choose the cup thickness based on the frequency of use: standard thickness for routine testing and thickened type for high-frequency applications. Check the smoothness of the cup opening and the clarity of the national standard markings. In corrosive environments, ensure the integrity of the coating.

Terms

Instruments

The copper Cup ensures durability, the diaMeter of the flow hole is 4mm with the capacity of 100ml, and the measurement time range is 0~ 150s, which is suitable for conditional viscosity determination.

$ 141.00

Measurement range 0-150 seconds, copper material is durable and in line with national standards, portable design is convenient for on-site rapid detection of Coating viscosity.

$ 123.00

Using copper nickel plating material, volume 37ml, in line with GB/T6750 standard, equilibrium hammer is hollow structure and filled with lead particles to adjust the weight, suitable for Coating and auxiliary materials, oil and other liquids specific gravity determination.

$ 106.00

Conical container design, Measurement range 10-150 seconds, flow hole diaMeter 4mm, can convert the outflow time to kinematic viscosity, support bakelite, aluminum, copper Cup body.

$ 131.00

Benchtop structure design, the upper cylinder and the lower cone, the diaMeter of the flow hole is 4 mm, the outflow time range is 0 to 150 seconds, and the metal material shall prevail to ensure the measurement accuracy.

$ 114.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Providing stable copper Ion concentration standards to ensure ElectRode Measurement accuracy, 250ml Encasement meets the daily calibrating needs of the laboratory and is suitable for a variety of copper ion detection scenarios.

$ 110.00

Aperture 4mm and capacity 100ml design, aluminum Cup body with bracket, improve measurement Stability and accuracy, suitable for standard viscosity test environment.

$ 127.00

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

Measurement range 0.00~ 5.00 ppm, accuracy +/- 0.05 ppm, using LED@575nm Illuminant, chemical reaction based rapid detection of copper Ion concentration, suitable for field and laboratory applications.

$ 215.00

Copper Cup with bracket structure, capacity 100 +/- 1ml, flow hole diaMeter 4mm, applicable to the flow time of 150 seconds or less viscosity test, through the flow time conversion kinematic viscosity value.

$ 167.00

The pure copper Cup body is used to ensure durability, the diaMeter of the 4mm flow hole is matched with the capacity of 100ml, the outflow time range is 0~ 150 seconds, and the correction coefficient K = 1 +/- 0.03 ensures the measurement accuracy, which meets the requirements of national standards.

$ 102.00

Bakelite Cup body and stainless steel filter, flow time 0~ 150 seconds, flow hole diaMeter of 4mm, capacity of 100ml, in line with GB/T 1723 standard, can be used with the bracket to improve Stability.

$ 122.00

Using 4mm flow hole and chrome-plated Cup structure, the outflow time range is 0-150 seconds, and the correction factor K = 1 +/- 0.03 ensures accurate and reliable viscosity measurement.

$ 115.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.