COD total phosphorus analyzer

The COD and total phosphorus analyzer employs chemical digestion and spectrophotometry, using strong oxidants to decompose organic matter and phosphorus-containing compounds in water samples, thereby measuring the concentrations of chemical oxygen demand and total phosphorus. It is used for water quality analysis in fields such as industrial wastewater treatment and environmental monitoring.
Selection
When selecting, focus on matching the measurement range with the sample type, check the instrument's detection limit and repeatability indicators, confirm the simplicity of the operational procedures, consider the stability of reagent and consumable supplies, and verify compliance with industry testing standards.

Terms

Standards

Instruments

With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.

$ 767.00

Measurement range 0.000~ 1.000mg/L, including 100mL molybdate solution, 25 packs of ascorbic acid powder and 25 packs of potassium persulfate powder, suitable for water quality total phosphorus detection.

$ 164.00

Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.

$ 4688.00

Adopt digestion Colorimetric integrated tube design, detection is safer and more convenient; Minimum display value of 0.001mg/L, Sensitivity is high; Support standard measurement and continuous measurement mode, built-in 4000 sets of data storage, to meet different detection needs.

$ 3268.00

15 minutes to quickly heat up to the set temperature, temperature control accuracy of +/- 0.5 ℃, using multi-point calibrated to eliminate temperature errors, standard imported Glass digestion tube resistant to sudden cooling and sudden heating without bursting.

$ 522.00

Colorimetric integrated tube design, sample digestion and result reading share a tube, no need to transfer liquid; more than 10 measurements of water samples and removal of abnormal values are averaged to reduce errors; built-in two COD detection methods, Measurement range 0-20000mg/L, detection limit as low as 2mg/L.

$ 3075.00

36-Hole design supports batch processing, temperature control accuracy of +/- 0.5 ℃, rapid heating to set temperature in 15 minutes, multi-point calibrating to eliminate measurement errors, standard imported glass tube anti-burst.

$ 580.00

16-Hole design to meet the needs of batch processing, 12 minutes rapid heating to 165 ℃, temperature control accuracy of +/- 1 ℃, equipped with a transparent shield for easy observation, support 5-999 minutes time adjustment.

$ 925.00

Colorimetric integrated tube design, supports more than 10 measurements to take the average value, measurement error ≤ +/- 5%, built-in 30,000 data storage and thermal printer, can expand the detection of ammonia nitrogen, total nitrogen and other paraMeters.

$ 2913.00

Colorimetric integrated tube operation, no liquid transfer; measurement error ≤ +/- 5%, Repeatability ≤ +/- %; Support Multi-ParaMeter detection and post expansion, built-in thermal printer and 30,000 data storage.

$ 4430.00

25-Hole Design Improves Sample Handling Efficiency, Temperature Control accuracy up to +/- 1 ° C to Ensure Digestion Stability, 12-minute rapid warming to 165 ° C to shorten waiting time, Transparent Shield for easy observation of the experimental process.

$ 1009.00

Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.

$ 285.00

Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.

$ 4688.00

Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.

$ 3268.00

Measurement range 0~ 1.5mg/L, resolution 0.01mg/L, eliminating human error and improving measurement accuracy.

$ 262.00