8L Tank Volume, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, equipped with maintenance-free pressure/suction pump, supports horizontal and vertical stirring to ensure uniform thermostatic.
Adopting digital control technology, constant speed closed-loop design ensures constant power operation at low speed, Max. Torque 900mNm, maximum viscosity 30000mPa · s, supports forward and reverse rotation and adjustable timing functions.
Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.
Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.
Adopt back heating structure and horizontal forced convection technology to ensure studio Temperature uniformity. Equipped with High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.5 ° C, supports 0-9999 minutes timing function, and has multiple Safety protection mechanisms.
Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.
The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.
Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.
Adopt deep closed-loop constant speed control, maintain constant Power operation at low speed; Max. Torque 650mNm, can handle liquids with viscosity up to 20000mPa · s; Rotation speed memory and timing functions.
Adopt back heating horizontal forced convection technology, Temperature Fluctuation +/- 0.5 ℃, Temperature range RT + 10~ 200 ℃. Sensor fault alarm, over-temperature protection and independent temperature limit Control system ensure the safety and reliability of the experiment.
Horizontal forced convection technology to ensure the studio Temperature uniformity, temperature control accuracy of 0.1 ℃ and Fluctuation +/- 1 ℃; Sensor fault alarm, over-temperature protection and 9999 minutes timing function, 304 stainless steel studio corrosion resistance easy to clean.
Temperature range -20~ 100 ℃, Temperature resolution 0.1 ℃, using TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuations, with 100 sets of program capacity and a variety of Safety protection functions.
PD array Detector and Φ 4mm measurement aperture, to meet the CIE V (lambda) 2 degree visual Response, compensation measurement to ensure High Accuracy and repeatability, open sample Chamber to adapt to vertical, horizontal testing, dynamic monitoring Illuminant and environment changes.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.