Simultaneous sampling ECT (100 * 25) mm and PAT (80 * 25) mm two sizes, sampling error +/- 0.5mm, thickness range ≤ 10mm, easy to operate.
Sampling size 25.4mm * 140mm, thickness range 0.05~ 1.2mm, parallelism of two long sides ≤ 0.015mm, to ensure High Accuracy sampling, Improve Test Reliability.
The sampling area is 100mm ² and the error is controlled within +/- 0.35cm ², which can handle 0.1~ 1.2mm Film thickness materials. The circular sampling design is used to ensure the standard of the sample, and the operation is simple and the results are reliable.
High sampling accuracy, parallelism ≤ 0.015mm, thickness range of 0.1~ 1.2mm, suitable for a variety of paper strength tests to ensure accurate and reliable detection data.
The bottom hole and tip design are adopted, and the outflow time is determined by observing the appearance of the tip, which realizes rapid viscosity measurement and is suitable for on-site testing needs.
Sampling area 100cm ², error +/- 0.35cm ², stamping sampling method, suitable for 0.1~ 1.0mm thickness materials, to ensure accurate sample standards.
The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, and the PID adaptive algorithm is equipped to ensure the Temperature Fluctuation +/- 0.5 ° C. The temperature uniformity is guaranteed by the design of the top orifice air supply.
Adopt multi-channel mechanical compression refrigeration system and adaptive throttling technology to achieve rapid temperature change of 5 ° C/min; Equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure temperature uniformity.
The bearing with accurate guidance and reasonable fulcrum structure, good sampling Repeatability, can handle materials with a thickness of 0.1-1 mm, support 70 * 38mm fold stiffness and 38 * 36mm crease stiffness two sizes, long side parallelism ≤ 0.015mm.
The linear guide is used to ensure smooth and fast sampling, and the imported tungsten sheet is cut without burrs and durable. It supports 18mm thickness sampling, and can cut 25 × 100mm and 25 × 80mm samples.
The sampling area is 100cm ², the sampling error is +/- 0.35cm ², the sampling thickness range is 0.1-3 mm, and the special treatment die blade is durable and free of replacement.
The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and the PID adaptive algorithm is equipped to ensure that the Temperature Uniformity is ≤ 2 ° C, and the 512L studio meets the diverse testing requirements.
Adopt multi-channel mechanical compression refrigeration system and frequency conversion technology to achieve rapid temperature change of 5 ° C/min; equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, support 120 groups of program editing and remote monitoring functions.
Measurement range 0-99.9%, resolution 0.1%, Response Time 1 second, portable design supports rapid on-site detection, probe Sensor can penetrate deep into the material internal measurement.
With a linear temperature rise and fall rate of 10 ° C/min and a wide temperature range of -60 to 150 ° C, multi-channel refrigeration system and PID adaptive algorithm are used to achieve rapid temperature convergence, and environmentally friendly refrigerants and low noise design are equipped.