Fully Automatic Balance

The fully automatic balance automatically weighs samples using the electromagnetic force balance principle, with built-in calibration weights and sensors to perform operations such as tare and piece counting. It is used in laboratories for rapid weighing of materials such as powders and liquids, and in the paint and ink industry, it is used in conjunction with a moisture analyzer to determine solid content.
Selection
When selecting, focus on the weighing range covering the sample weight, ensure readability meets precision requirements, check that the automatic door and draft shield structure are suitable for the operating environment, confirm the availability of internal calibration functions, verify interface compatibility with the laboratory data system, and consider the corrosion resistance of the sample tray material.

Terms

Standards

Instruments

Adopt electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure calibrating accuracy. Equipped with negative LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 2171.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing accuracy.

$ 1203.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow star pan design, effectively reduce airflow and static interference, improve weighing accuracy and Stability.

$ 2171.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, internal use of non-magnetic weight to ensure the accuracy of calibrating, and equipped with anti-static Glass and hollow star pan to reduce airflow and static interference, improve Weighing Accuracy.

$ 2010.00

Using electromagnetic force equilibrating Sensor and automatic timing internal calibrating, equipped with non-magnetic weight to ensure accuracy, with negative LCD screen, anti-static Glass and hollow pan design, effectively reduce airflow and static interference, improve weighing Stability.

$ 1848.00

Adopt a new generation of High Accuracy Sensor to ensure stable and reliable weighing, with a reaction time of less than 2 seconds, a fully automatic internal calibration function triggered by time and temperature, and support for a variety of weighing units.

$ 935.00

Using electromagnetic force equilibrating Sensor, with automatic timing internal Adjustment, built-in non-magnetic weight to ensure calibrating accuracy. Equipped with negative display LCD screen, anti-static Glass and hollow star Luo pan, effectively reduce airflow and static interference, improve weighing Accuracy.

$ 2494.00

Using positive pressure test principle, Measurement range 0~ 1.6MPa, fully automatic operation, support three test modes, built-in calibrating program, suitable for quantitative measurement of various sealing performance indicators.

$ 1332.00

Adopt electromagnetic force equilibrating Sensor, automatic timing internal calibrating, equipped with non-magnetic weight to ensure calibrating accuracy, negative LCD screen is clear and easy to read, anti-static Glass and hollow pan design effectively reduce interference, improve weighing Stability and accuracy.

$ 1687.00

Using electromagnetic force equilibrating Sensor, automatic timing internal calibrating to ensure accuracy, equipped with negative LCD screen, anti-static Glass and hollow star pan to improve weighing accuracy and Stability, support a variety of communication and printing functions.

$ 2494.00

Using high-performance MCS-51 single chip microprocessor control, weighing range 0-110g, accuracy 1mg, with RS232C output interface and automatic correction function to ensure high weighing results Accuracy.

$ 412.00

The fully automatic electronically controlled hydraulic pump provides smooth and continuous pulling force with +/- 1% accuracy, built-in rechargeable battery supports 200 tests, and IP65 Protection Rating ensures durability.

$ 4212.00

Adopt high-performance single-chip microprocessor control, weighing range 0-120g, accuracy 1mg, with RS232C interface can be directly connected to external devices, support cumulative weighing and unit conversion functions.

$ 412.00

Equipped with a 5-inch color Touchscreen for easy operation, a new generation of electromagnetic force equilibrating Sensor for fast and stable weighing, fully automatic time trigger calibrating to ensure accuracy, Stabilization time ≤ 3 seconds, support density and percentage functions.

$ 582.00

Automatic time trigger internal calibrating, a new generation of electromagnetic force equilibrating Sensor, weighing fast and stable, repeatability error +/- 0.0002g, Stabilization time ≤ 3 seconds, strong anti-static and anti-interference ability.

$ 485.00

Articles

A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Summary of Balance Selection for Different Application Scenarios
This article discusses how to choose a balance based on usage needs. First, you need to understand the basic parameters of a balance, such as its maximum capacity and precision.
Grade classification of balances based on different repeatability indicators
The repeatability of a balance refers to the consistency of multiple weighing results for the same load under identical conditions, which is a key indicator for evaluating the performance of a balance. It is typically expressed as the standard deviation or range, with smaller values indicating greater stability and reliability of the balance.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Selection Considerations for Balances with Different Weighing Pan Materials
When selecting the material of the balance weighing pan, it is necessary to comprehensively consider the sample properties, measurement environment, and operational requirements.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Which one to choose: built-in calibration or external calibration balance?
This article primarily compares the two calibration methods for balances: internal calibration and external calibration.
Differences in the Selection of Analytical Balances and Precision Balances
Analytical balances and precision balances are both high-precision weighing instruments commonly used in laboratories, but they differ primarily in terms of accuracy and application scenarios.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.