Adhesive Blending Machine

The adhesive mixer uses an electric motor to drive the rotation of blades, ensuring uniform mixing of all components of the adhesive. It is used in laboratories or production settings to thoroughly stir materials such as resins and curing agents, preventing stratification or clumping and ensuring stable adhesive performance.
Selection
When selecting an adhesive mixer, consider the viscosity of the material: choose a low-speed, high-torque model for high-viscosity materials. Match the length of the mixing paddle to the container size. Ensure the motor power is suitable for the load to avoid overheating. The material should be corrosion-resistant, such as stainless steel. The operation should be simple and include speed adjustment functionality.

Terms

Standards

Instruments

Provides irreversible temperature recording with accuracy of +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C. Self-adhesive design, resistant to oil, water and steam, ensures reliable monitoring.

$ 98.00

Irreversible discoloration record historical temperature, accuracy +/- 1 ° C to +/- 4 ° C, oil, water and steam resistance, self-adhesive design for easy installation and storage.

$ 98.00

Suitable for a variety of Corrugated Board adhesive strength test, equipped with different specifications of steel needles, needle diaMeter range 1.0-3 mm, support A, B, C, E corrugated test, sample size 25 × 80mm.

$ 222.00

Irreversible discoloration provides permanent temperature recording, Measurement accuracy +/- 4 ℃, oil resistance, water resistance and steam resistance, self-adhesive design for easy installation, Response instant no power supply, size 12 * 13mm compact and portable.

$ 98.00

Irreversible Color change for long-term temperature recording; Resistant to oil, water and steam; Temperature accuracy is +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C; Self-adhesive design for easy use and storage.

$ 93.00

Irreversible discoloration provides long-term temperature recording, Measurement accuracy +/- 1 ℃ to +/- 4 ℃, oil resistance, water resistance and steam resistance, self-adhesive design is easy to use, temperature grid size 12 * 13mm round.

$ 96.00

Irreversible discoloration record historical temperature, Measurement accuracy +/- 1 ℃ to +/- 4 ℃, oil and water vapor resistance, self-adhesive design for easy installation, Instant Response.

$ 96.00

Irreversible discoloration records the highest temperature, self-adhesive design for easy installation. Measurement accuracy +/- 1 ° C to +/- 4 ° C, oil and water vapor resistance, round single cell structure size 12 * 13mm, providing long-term temperature history.

$ 98.00

Using irreversible Color change technology, six-grid temperature measurement range of 132 ° C to 160 ° C, accuracy +/- 1.5 ° C, oil and water vapor resistance, self-adhesive design for easy installation and long-term recording.

$ 93.00

Equipped with 8 Meters Oven, roller heating temperature up to 200 ℃, effective application width 500mm, Spreader thickness range 0.005-3mm, support automatic unwinding to winding process, suitable for hot-melt adhesive film.

$ 29120.00

Irreversible discoloration provides permanent temperature recording, Measurement accuracy +/- 1 ℃, oil and water vapor resistance, self-adhesive design for easy installation, circular single grid structure size 12 * 13mm.

$ 96.00

Measurement accuracy +/- 1 ° C to +/- 4 ° C, oil-resistant, water-resistant and steam-resistant, self-adhesive design for easy installation, temperature grid discoloration is obvious and easy to identify.

$ 96.00

Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.

$ 524.00

Irreversible discoloration provides long-term temperature recording, self-adhesive design for easy sticking, oil, water and steam resistance, accuracy below 100 ° C is +/- 1 ° C, Response is instant and inexpensive.

$ 96.00

Irreversible discoloration record temperature history, accuracy within 100 ° C +/- 1 ° C, oil and water vapor resistant, self-adhesive design easy to paste and remove, size 12 * 13mm, 50 sheets per copy.

$ 98.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Application of Initial Tack Tester in the Detection of Pressure-Sensitive Hot Melt Adhesives
The initial tack tester is a device used to measure the initial adhesive properties of pressure-sensitive hot melt adhesives, primarily by employing the rolling ball method or probe method to assess the adhesive force at the moment of contact.
Operation Tips for Laboratory-Scale Hot Melt Adhesive Coating Machines
This article introduces the key operational points of a laboratory-scale hot melt adhesive coater. The equipment is primarily used in laboratories to apply hot melt adhesives uniformly onto substrates, supporting the research, development, and testing of adhesives.
Sag resistance and leveling in constructability evaluation
This article primarily discusses how to balance the two key properties of sag resistance and leveling during the application of materials such as coatings and adhesives. Sag resistance refers to the material's ability to resist sagging due to gravity on vertical surfaces, while leveling refers to the material's ability to automatically smooth out its surface after application.
Tensile testing machine for testing the tensile shear strength of adhesives
This article introduces the method for testing the tensile shear strength of adhesives using a tensile testing machine. Tensile shear strength is a key indicator for evaluating the mechanical properties of adhesives. During the test, a bonded standard specimen is clamped into the testing machine and stretched at a constant speed until failure. The maximum load is recorded, and the strength is calculated accordingly.