Circulating Air Oven

The circulating air oven drives hot air to flow uniformly inside the chamber through a fan, ensuring consistent heating of samples. It is used in laboratories for drying, curing, or heat treatment of materials, such as paint drying and plastic aging tests.
Selection
When selecting, consider matching the temperature range with sample requirements, ensuring the chamber size accommodates the sample volume, the temperature control accuracy meets testing needs, the fan noise and energy consumption comply with the usage environment, and the material's corrosion resistance is suitable for the substances being processed.

Terms

Standards

Instruments

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.

$ 1474.00

The studio is made of mirror stainless steel with a volume of 130L, equipped with three-sided circulating air ducts to ensure temperature uniformity, and an independent temperature limiting controller provides double protection. Temperature Fluctuation is controlled within +/- 1%.

$ 672.00

The studio is made of mirror stainless steel, with a volume of 70L and a temperature control accuracy of +/- 0.5 ° C. It is equipped with an independent temperature limiter and a three-sided circulating air duct to ensure temperature uniformity and operation safety.

$ 512.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy of +/- 1.0 ℃, turbine centrifugal fan blade with the drum design, fan speed adjustable, studio mirror stainless steel easy to clean.

$ 1248.00

The studio is made of mirror stainless steel with a volume of 230L, equipped with independent temperature limiting controller and three-sided circulating air duct to ensure temperature uniformity, temperature control accuracy +/- 0.5 ° C, and support 0~ 999min timing function.

$ 816.00

Vertical double air duct vertical hot air circulation to ensure uniform temperature distribution, temperature control accuracy of +/- 1.0 ℃, equipped with large screen LCD display and independent temperature limit alarm system, support 1-9999 minutes timing function, effectively ensure the safe and stable operation of the experiment.

$ 3410.00

Adopt hot air circulation system to ensure Temperature uniformity, Temperature Fluctuation +/- 1 ℃, volume 30L, with over temperature deviation protection and timing function, can adjust the air inlet and exhaust volume.

$ 453.00

Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.

$ 603.00

Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.

$ 958.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?