Vertical Oscillating Incubator

The vertical oscillating incubator drives the tray in a reciprocating motion through an electric motor, causing continuous agitation of the liquid in the container to promote oxygen dissolution and material mixing. It is used for biochemical reaction processes such as microbial fermentation and cell culture, commonly found in laboratory microbial propagation and sample pretreatment.
Selection
When selecting, consider the oscillation frequency range and stability, ensure the tray size matches commonly used culture vessels, and the temperature control accuracy meets experimental requirements. Pay attention to operational noise levels and safety protection features, choose materials that are corrosion-resistant and easy to clean, and select an appropriate chamber volume based on available space.

Terms

Standards

Instruments

Vertical double air duct air sleeve structure with turbine centrifugal forced air supply, Temperature Uniformity +/- 1.0 ℃, speed regulating fan supports lightweight and small samples, low water level alarm and forced heat dissipation to ensure safe operation.

$ 993.00

Vertical double air duct air sleeve structure with turbine centrifugal forced air supply, Temperature Uniformity +/- 1.0 ℃, Fluctuation +/- 0.5 ℃, support speed regulating fan to adapt to lightweight samples, low water level alarm and forced heat dissipation to ensure safe operation.

$ 1248.00

The fixture can fix the upper and lower ends of the butterfly specimen into a vertical shape, test the vertical compression strength, suitable for a variety of Corrugated Board types, Dimension 150 * 105 * 65mm, weight about 2Kg, easy to operate.

$ 596.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Temperature control accuracy +/- 0.2 ℃, Temperature Uniformity ≤ +/- 0.3 ℃, DC brushless motor drive maintenance-free, with power-off automatic recovery and 0-100 hours timing function, support a variety of module replacement.

$ 908.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Support forward and reverse rewinding and unwinding functions, with tension control and deviation correction functions, vertical mesh running speed 1mm/s to 1m/min, effective coating area 1500 * 600mm, to ensure that the mesh vertical stability without shaking.

$ 14274.00

Vertical design with bottom drum and bottom heater, turbine centrifugal fan blade to achieve vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, studio volume 125L, PID microcomputer intelligent temperature control to ensure uniform and stable temperature.

$ 958.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.

$ 603.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Articles