DIN Efflux Cup

The DIN flow cup measures the time it takes for paint to flow out from a standard hole at the bottom of the cup to reflect viscosity. The cup body is conical with a fixed aperture, and the outflow time is proportional to the viscosity. It is used for on-site rapid testing of the fluidity of paints and inks, guiding dilution and adjustments during application.
Selection
Select the corresponding aperture model based on the viscosity range of the material being tested, with larger apertures for high viscosity. Consider the particle size of the material to avoid clogging, and verify the corrosion resistance of the cup material. Record the impact of ambient temperature and ensure it matches the viscosity requirements of the production process.

Terms

Standards

Instruments

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Adopt replaceable filter design, support 1-8mm aperture selection; Cup annular groove can store overflowing liquid, Cup wall has no clean dead angle; comply with DIN53211 standard, with unique serial number for easy tracking.

$ 441.00

Replaceable 1-8mm aperture stainless steel filter, Cup mouth annular groove design to store overflow liquid, Cup body made of titanium anodic oxidation aluminum, outflow hole diaMeter 6mm, easy to clean and equipped with a unique serial number.

$ 420.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

Conform to DIN 53211 standard, evaluate viscosity by measuring 100ml liquid outflow time, 4mm pore size design is suitable for 112~ 685cSt viscosity range, outflow time is 25~ 150 seconds, anodic oxidation aluminum alloy Cup body corrosion resistance.

$ 130.00

The filter diaMeter of 1-8mm can be freely replaced, the Cup mouth annular groove is designed to store overflow liquid, titanium anodic oxidation aluminum Cup body with stainless steel filter positioner, the distance between the outflow hole and the liquid level should be greater than 100mm.

$ 436.00

With replaceable filter design, covering the aperture range of 1-8mm, the Cup body annular groove stores the overflowing liquid, the outflow time is 25-150 seconds, and the titanium anodic oxidation aluminum material ensures durability and easy cleaning.

$ 420.00

In line with DIN 53211 standard, the outflow time is 25~ 150s, the viscosity range is 15~ 30cSt, and the aluminum alloy Cup body and stainless steel nozzle are used to quickly test low viscosity liquids.

$ 135.00

Adopt aluminum alloy Cup body and stainless steel nozzle structure, the outflow aperture is 2mm, the viscosity measurement range is 15~ 30cSt, which is suitable for low viscosity thin liquid test, and the outflow time is controlled at 25~ 150 seconds.

$ 130.00

Using anodic oxidation aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 8mm, and the viscosity measurement range is 1200~ 3000cSt, which is suitable for the pRoduction line to quickly test the sample viscosity, and the outflow time is controlled at 25~ 150 seconds.

$ 135.00

Made of stainless steel, the flow hole diaMeter is 2mm, according to DIN 53211, providing accurate viscosity measurement for Newtonian or near newtonian fluids.

$ 581.00

Adopting anodic oxidation aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 6mm, the viscosity measurement range is 550~ 1500cSt, and the outflow time is 25~ 150 seconds, which is suitable for rapid viscosity testing of pRoduction lines.

$ 135.00

Using aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 4mm, the viscosity measurement range is 112~ 685cSt, and the outflow time is 25~ 150s, which is suitable for rapid testing of sample viscosity on the pRoduction line.

$ 135.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.