Multi-functional Oven

The multifunctional oven heats air through electric heating elements and uses a fan to circulate hot air, ensuring uniform temperature inside the chamber. It is used for drying, curing, and aging samples, and is employed in industries such as coatings and plastics for material heat treatment and quality testing.
Selection
When selecting, consider the temperature range and fluctuation to meet processing needs, ensure the chamber volume fits the sample size, and check the inner chamber material for corrosion resistance. Pay attention to heating rate and uniformity indicators, and choose programmable temperature control, explosion-proof, or vacuum functions as needed.

Terms

Standards

Instruments

16Mm large diaMeter is suitable for striped fabric and leather measurement, Repeatability Delta E * ab < 0.05, with multi-functional test components can measure liquid, powder and other samples to improve measurement accuracy.

$ 1897.00

Temperature range RT + 5~ 60 ℃, Oscillation Frequency 0~ 320rpm, support rotary and reciprocating oscillation mode, liner made of stainless steel corrosion resistance, stepless speed control smooth operation.

$ 883.00

Maximum pull-out force 40kN, using three-point reaction support and post-loading pull-out method principle, with color Touchscreen display force value and time Linear dispersion, support automatic storage of 10000 data.

$ 837.00

With 0~ 300rpm stepless speed regulation and 20mm swing amplitude, the multi-functional spring bottle test rack supports a variety of comparison experiments, and the low center of gravity of the whole machine ensures stable and reliable continuous work.

$ 298.00

Equipped with multi-functional test components to measure liquid and powder samples, 8mm measurement caliber to ensure accurate positioning, Repeatability fluctuation is less than 0.07 on average, light positioning function simplifies the operation process.

$ 1655.00

With a multi-functional spring bottle test rack, it supports a variety of comparative experiments; the stepless speed range is 0~ 250rpm, and the pendulum amplitude is 25mm; the center of gravity of the whole machine is low, and the continuous work is stable and reliable.

$ 364.00

Temperature control accuracy of +/- 1 ℃, Oscillation Frequency start~ 300rpm, with oxygen holes to ensure full oxygen, equipped with multi-functional spring bottle rack for a variety of comparative experiments, stepless speed control smooth operation and safety.

$ 503.00

The independent control of the dual temperature zone can simultaneously digest different paraMeters, the 30-hole design supports digestion capacity above 12mL, the temperature control accuracy is +/- 0.5 ° C, the temperature is raised to 165 ° C within 12 minutes, and the fully enclosed transparent protective cover ensures safety.

$ 1977.00

Temperature control accuracy, 0~ 320rpm stepless speed, stainless steel cavity corrosion resistance, multi-functional spring bottle rack for a variety of comparative tests.

$ 704.00

304 stainless steel material to prevent rusting, Tapped Density vibration amplitude 1-15mm adjustable, equipped with Hall Flow velocity Meter function, support 3 different volume measuringflask test, to meet a variety of international standards.

$ 5528.00

The frequency conversion motor is used to achieve stepless speed regulation of 60~ 8000rpm, and the digital PID control accuracy is high. It is equipped with dispersed impellers and sand grinding blades to adapt to different experimental needs, and the relationship between material viscosity and reaction rate can be directly calculated.

$ 711.00

Temperature control accuracy of +/- 0.1 ℃, Oscillation Frequency 0-320rpm, using multi-functional spring bottle test rack, suitable for a variety of comparative tests, smooth operation and easy operation.

$ 1042.00

Maximum load 5KN, suitable for a variety of material testing, multi-functional design can be adapted to different samples, stable and reliable clamping, to meet the laboratory's diverse mechanical properties testing needs.

$ 332.00

Microcomputer Controlled Temperature Frequency Time, Large Screen LCD Display Three ParaMeters, Low Heat Dispersion Brushless DC Motor Provide 40~ 300rpm Wide Speed Regulation, With Automatic Stop and Load Regulation Functions.

$ 638.00

Temperature control accuracy of +/- 0.1 ℃, Oscillation Frequency 0-320rpm, support for swirling and reciprocating oscillation, multi-functional spring bottle rack for comparison test, easy to operate, safe and smooth operation.

$ 1284.00

Articles

Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Key Technical Points for Determining Paper Moisture Using the 105℃ Oven Method
This article introduces the specific procedure for measuring paper moisture using the 105°C oven method. The process involves placing paper samples into a 105°C oven and drying them until their weight remains constant, then calculating the moisture content based on the weight difference before and after drying.
Oven combined with analytical balance for determination of solid content
This article introduces a method for determining the solid content of samples in the laboratory by combining an oven and an analytical balance.
Temperature gradient control in high-temperature ovens during thermal resistance testing.
The heat resistance test simulates the performance of materials under high temperatures using a high-temperature oven, and the accuracy of its results is highly dependent on the uniformity of temperature inside the oven. If the temperature gradient is poorly controlled, it can lead to uneven heating of samples from the same batch, compromising the validity of the test.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?