With 350~ 9999ppm wide range detection range, Response Time of about 90 seconds, support sound and light dual alarm, built-in temperature measurement function, portable design weighs only 170 grams.
Electrochemical sensor is used to detect CO gas, with a range of 1~ 1000ppm, a resolution of 1ppm, and a Response Time of less than 60 seconds.
ABS + PC shell is sturdy and durable, equipped with 2.0 inch 320 * 240 resolution display screen, supports methane, O2, H2S, CO four Gas detection, Response Time is the fastest 20 seconds, battery life is 8 hours, with sound and light vibration triple Alarm mode.
Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 recovery time ≤ concentration value × 1.2min, built-in ultraviolet sterilization lamp and microbial Filter, effectively prevent foster pollution, the use of antibacterial stainless steel lumen for easy cleaning and maintenance.
Using microcomputer module control, CO2 control accuracy of 0.1%, temperature resolution of 0.1 ℃, equipped with CO2 and gas dual filtrate device, liner four corners arc design for easy cleaning.
Using Infrared Sensor to monitor CO2 concentration, not affected by Temperature Humidity, CO2 concentration recovered within 5 minutes after opening the door, Temperature Fluctuation +/- 0.2 ℃, equipped with Microbial Filter and door temperature heating system to prevent condensation pollution.
Equipped with infrared CO2 sensor accuracy of 0.1%, CO2 uniformity +/- 0.1%, built-in UV sterilization lamp and microbial Filter, antibacterial stainless steel inner cavity four corners arc design for easy cleaning, support programmatic programming and Linear dispersion display function.
Water-jacketed heating method is adopted, the temperature control accuracy reaches +/- 0.3 ℃, with CO2 concentration control and alarm function, the liner four-corner arc design is easy to clean, and the door heating device prevents condensation.
Infrared CO2 Sensor Response Fast, Not Affected by Temperature Humidity, CO2 Recovery Time ≤ 3 minutes; Circulating wind speed automatically adjusts to avoid sample volatilization; Door temperature heating prevents condensate pollution.
Infrared Sensor is used to monitor CO2 concentration, which is not affected by temperature and Humidity, and restores the set CO2 value within 5 minutes after opening the door; Equipped with Microbial Filter, the filtration efficiency of ≥ 0.3 μm particles reaches 99.99%, effectively preventing pollution.
Using infrared CO2 Sensor control accuracy +/- 0.1%, gas sleeve heating heating, CO2 recovery time does not exceed the concentration value × 1.2 minutes, double door structure sealing good anti-pollution.
Equipped with infrared CO2 sensor accuracy of 0.1%, with ultraviolet sterilization and door heating anti-condensation design, CO2 recovery time ≤ concentration value × 1.2 minutes, support RS-485 interface connection.
Using electrochemistry and catalytic combustion Sensor to detect EX/O2/CO/H2S four gases, Response Time is less than 30 seconds, with waterproof ABS shell and sound and light vibration triple alarm, battery life of 8 hours.
Equipped with infrared CO2 sensor accuracy of 0.1%, built-in ultraviolet sterilization lamp can effectively prevent pollution, support 0-20% CO2 concentration range, the use of antibacterial stainless steel cavity for easy cleaning and maintenance.
Using Infrared CO2 Sensor, restore 5% concentration within 3 minutes after opening the door; Equipped with 90 ℃ heating and humidity sterilizing system, effectively eliminate microbial pollution; Temperature Fluctuation +/- 0.1 ℃, CO2 control accuracy +/- 0.1%.