Equipped with seven shafts of different diaMeters and a minimum radius of curvature of 0.5mm, the flexibility of the paint film can be accurately measured at 180 ° bending under standard temperature Humidity conditions.
The equipment can perform a 45 ° bending test, support 0.5~ 1.0mm plate thickness, equipped with Travel ≥ 10mm flattening mechanism, suitable for accurate testing of coating flexibility.
Equipped with seven steel shaft Rods of different diaMeters, the radius of curvature covers 0.5mm to 7.5mm, and the shaft Rod length is 50mm, which can accurately test the film flexibility under standard temperature Humidity conditions.
It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.
It can test the cracking of the paint film after bending 180 degrees in 1-3 seconds, and the diaMeter range of the shaft Rod is 2-32mm. It is suitable for the test plate with a thickness of not more than 1.0mm. Quick evaluation of flexibility.
Equipped with 7 different diaMeter shaft Rods, the length of the shaft Rod is 35mm, and the minimum radius of curvature is 0.5mm, which can accurately determine the film flexibility according to the standard requirements.
Equipped with two kinds of shaft Rods with diaMeters of 100mm and 50mm, it can simulate the actual stress conditions, and make the sample uniform bending and deformation through the rolling shaft, which is convenient for observing the phenomenon of film crazing and peeling.
The non-heat centrifugal circulating pump is used to ensure uniform insulation field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices such as low water level anti-dry burning and Compressor overcurrent protection, optional temperature control and external Sensor to enhance application flexibility.
Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and magnetic stirring system to enhance experimental flexibility.
Adopt non-heat centrifugal circulating pump to avoid self-heating affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control or magnetic stirring function to enhance application flexibility.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to enhance experimental flexibility.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to enhance experimental flexibility.
The equipment is equipped with 12 sets of stainless steel clamps with a bending angle of 22.5 °, allowing multiple test pieces to be tested simultaneously. The LCD liquid crystal counter accurately records the number of bends from 0 to 999999.
The bending diaMeter of putty film cracking peeling is tested by bending test plate, and the shaft Rod size is 50mm and 100mm. It is suitable for 0.2-0 mm thick tinplate substrate, and the operation is simple and reliable.
Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.