Graphite Stirrer

The graphite stirrer utilizes the corrosion resistance and thermal conductivity of graphite materials, driven by a motor to mix reaction materials with its stirring paddle. It is used for stirring solutions in acidic and alkaline environments, preventing metal contamination, and is commonly employed in the chemical and electroplating industries for handling corrosive liquids.
Selection
When selecting, consider matching the reactor size with the stirring power. Use high-purity graphite for highly corrosive conditions, and choose an oxidation-resistant coating for high-temperature environments. Verify the compatibility of interfaces with the equipment, adjust the blade shape based on viscosity, and regularly inspect the shaft seal to prevent leaks.

Terms

Standards

Instruments

Using high purity graphite material and fuzzy PID temperature control technology, temperature control accuracy +/- 0.1 ℃, with over-temperature alarm, temperature self-setting and thermostatic timing function, panel size 400 * 300mm.

$ 808.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.

Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.

Graphite electRode to reduce Polarization effect, automatic temperature compensation to ensure accuracy, Measurement range EC 0-3999μS/cm, TDS 0-2000ppm, resolution up to 1μS/cm, suitable for harsh environments.

$ 306.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment needs.

Temperature control accuracy of +/- 0.1 ℃, using fuzzy PID control technology, with over-temperature alarm and temperature self-tuning function, heating material is high purity graphite, panel size 600 * 400mm.

$ 1332.00

It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.

$ 1927.00

Temperature control accuracy +/- 0.1 ℃, Temperature range RT +~ 450 ℃, using fuzzy PID control to achieve fast stability and small overshoot, with over-temperature alarm and self-tuning function, heating material is high purity graphite.

$ 912.00

PID microchip control to achieve +/- 0.5 ℃ temperature control accuracy, surrounded by heating to ensure that the temperature difference between holes ≤ +/- 1 ℃, high purity graphite heating material acid and alkali corrosion resistance, double-decked insulation design to improve safety and efficiency.

$ 1558.00

Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.

Using fuzzy PID temperature control technology, the temperature overshoot is small and the Stabilization time is fast; the temperature control accuracy reaches +/- 0.1 ℃, the panel size is 600 * 400mm; with over-temperature alarm and self-tuning function, to ensure the safety and accuracy of the experiment.

$ 1227.00

Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Using PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure the same batch of sample digestion effect, simple and efficient operation.

$ 2849.00

The instrument adopts PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure consistent digestion of the same batch of samples, equipped with abnormal alarm and double-decked insulation system.

$ 1219.00