Binocular Laboratory Microscope

A binocular microscope creates stereoscopic vision through two independent optical paths and eyepieces, using objective lenses to magnify sample details. It is used to observe the surface texture and structural morphology of objects, as well as to examine three-dimensional specimens in fields such as material testing and biological dissection.
Selection
When selecting, consider matching the magnification to the size range of the observation sample. Choose a monocular or binocular structure based on the usage environment. The combination of eyepieces and objectives affects the field of view, and the working distance must accommodate the operational space. For prolonged use, pay attention to adjusting the interpupillary distance and ensuring the comfort of the eyecups.

Terms

Standards

Instruments

Using binocular stereo Microscope observation, support capillary method and hot table method two measurement methods, temperature resolution of 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), with Draft Shield to reduce environmental impact.

$ 875.00

Adopt hinged binocular observation head, with adjustable pupil spacing of 55-75mm, total magnification of 40X-1600X, equipped with Abbe condenser and double-decked mechanical stage, support for phase contrast, dark field and other accessories expansion.

$ 603.00

Equipped with 4X-100X color difference objective lens and WF10X-WF16X large field of view eyepiece, hinged binocular head can be swirl/spin 360 degrees, coaxial coarse fine-tuning system provides 20mm focusing range, condenser NA = 1.25 with variable light bar.

$ 574.00

Equipped with binocular observation head and four-hole objective lens converter, with a total magnification of 40X-1000X, support for 360 ° rotating stage and coaxial coarse fine-focusing system, suitable for structural analysis of birefringent substances.

$ 751.00

The planetary coaxial coaxial fretting focusing device is used for comfortable and stable focusing; the total magnification is 40X-1600X, and it is equipped with a liftable Abbe condenser and a double-decked mechanical stage to observe unstained specimens clearly.

$ 1977.00

The 195 color difference objective improves the image contrast ratio, supports 40X to 1600X magnification range, and is equipped with a liftable Abbe condenser and a double-decked mechanical stage to ensure comfortable and accurate observation.

$ 525.00

Equipped with infinity flat field color difference elimination objective lens and large field of view eyepiece to provide high-quality Optical Properties; using 3W LED cold Illuminant lighting and coaxial coarse fine-tuning system, the fine-tuning grid value reaches 0.001mm, and the operation is comfortable and accurate.

$ 1977.00

Optical inspection system with infinity, equipped with 4X-100X flat field color difference elimination objective lens and WF10X-16X large field of view eyepiece, providing NA1.25 condenser lens and 0.001mm fine-tuning accuracy, support phase contrast observation function, comfortable and convenient operation.

$ 1913.00

Heavy-duty stainless steel structure ensures stable support, equipped with 3 strong magnets for firm adsorption, maintaining the vertical state of Microscope, suitable for various metal surface fixing needs.

$ 339.00

Provides 40x magnification and a 0.60 numerical aperture to ensure high resolution and long working distances for a variety of Microscope applications.

$ 138.00

Provide single polarized, orthogonal polarized and conical observation, total magnification 40X~ 1000X, coarse micro coaxial focusing system, fine-tuning accuracy of 0.01mm, built-in dimming high luminance LED lamp.

$ 925.00

Made of aluminum, Dimension 150 * 220 * 290mm, support 360 ° swirl/spin adjustment and arm adjustable, suitable for a variety of Microscope models.

$ 154.00

Optical inspection system with infinity, support 40X-1600X magnification range, with Abbe condenser and coaxial focusing mechanism, can realize high-resolution real-time observation and digital storage function.

$ 1213.00

Equipped with 5 million pixel CMOS camera, supports real-time observation and image recording, magnification 40X-1600X, digitalization imagery and image measurement analysis functions, improve observation flexibility.

$ 641.00

With 1:6.4 continuous zoom ratio and 105mm long working distance, large field of view and high resolution, durable and reliable operating mechanism, complete accessories, support a variety of lighting adjustment.

$ 1184.00

Articles

Comparison of Selection Between Dual-Column Gantry and Single-Column Universal Testing Machines for Plastic and Rubber Testing
This article compares the differences between dual-column portal and single-column universal testing machines in plastic and rubber testing. Dual-column portal types offer high rigidity and large load capacity, making them suitable for high-strength materials and high-precision testing; single-column types have an open structure and low cost, making them ideal for small loads and frequent fixture changes.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.