Gel Time Automatic Tester

The gel time automatic tester determines the transition time of resins or coatings from liquid to solid by heating the sample and monitoring viscosity changes. It is used in production control and quality inspection to ensure that materials meet set standards during processes such as coating and curing.

Instruments

Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.

$ 509.00

Aluminum alloy working platform and long life heating tube, Temperature range RT +~ 550 ℃, temperature error +/- 1 ℃, equipped with PID intelligent temperature Control system, can be customized heating Platform size according to demand.

$ 685.00

Using copper plate working platform and long life heating tube, PID intelligent temperature control to achieve +/- 1 ℃ accuracy, Temperature range RT + 10~ 300 ℃, with automatic thermostatic function, easy to operate.

$ 1009.00

The 10x30mm standard size design ensures a perfect match with the SH1117 Tester, providing accurate gel strength measurement results.

$ 694.00

Using Platinum Sensor and Gel KCL Reference Solution, Operating temperature range is 0~ 60 ℃ to ensure stable reference potential and good sensing ability.

$ 115.00

Built-in temperature resistor real-time sensing sample temperature, gel KCL reference solution to ensure long-term stability of ElectRode, Measurement range 0~ 14pH, suitable for a variety of liquid environments.

$ 96.00

Frequency adjustable continuously, stable operation and low noise, the device is suitable for gel treatment, molecular hybridization and X-ray film Development, etc.

$ 267.00

Working Frequency 0-240rpm continuously adjustable, equipped with 340 * 250mm tray, support swing oscillation mode, low running noise and stable performance, suitable for gel treatment and molecular hybridization and other experimental scenarios.

$ 180.00

Using plastic shell with 1 Meter BNC interface cable, specification is Φ 12mm × 120mm, built-in 3mol KCl gel reference solution without maintenance, Measurement range 0-14pH and 0-60 ℃, suitable for a variety of detection scenarios, providing stable and accurate acid alkalinity measurement.

$ 88.00

Using automatic time trigger internal calibrating, the new generation of electromagnetic force equilibrating Sensor ensures fast and stable weighing, repeatability error +/- 0.0002g, Stabilization time ≤ 3 seconds, special precision casting aluminum shell to improve anti-static and anti-interference ability.

$ 474.00

Automatic time trigger internal calibrating, a new generation of electromagnetic force equilibrating Sensor, weighing fast and stable, repeatability error +/- 0.0002g, Stabilization time ≤ 3 seconds, strong anti-static and anti-interference ability.

$ 485.00

It can measure drying time from 1 minute to 48 hours, with accuracy up to 10 seconds, and has intelligent recording function to improve the resolution of long drying process, which is suitable for various coating types.

$ 1649.00

Automatic Time Trigger Internal Adjustment, Reading accuracy 0.001g, Stabilization time ≤ 3 seconds, Electromagnetic Force equilibrating Sensor ensures fast and stable weighing, Three-door Glass Draft Shield provides large operating space.

$ 453.00

Adopt a new generation of electromagnetic force equilibrating Sensor, weighing fast and stable and Stabilization time ≤ 3s; Special precision casting aluminum shell improves anti-static and anti-interference ability, supports automatic time trigger calibrating and one-button Adjustment.

$ 485.00

The drying process of paint film and putty film can be accurately measured by using circular track needle design, equipped with four different radius needle (R0.25/0.5/1.0/1 mm), and the track period is 24h/r.

$ 223.00

Articles

Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machine in Waterproof Coating Finishing of Textiles
Automatic film coating machines are used for waterproof coating finishing on textiles, enabling precise control of coating thickness, improving uniformity and production efficiency.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium Battery Separators
This article introduces the application of automatic coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Key operational points for determining the acid value of oils and fats using potentiometric titration.
This article introduces the key operational points for determining the acid value of oils and fats using potentiometric titration. The method principle involves dissolving the oil or fat sample, titrating it with a standard alkaline solution, automatically determining the endpoint based on the potential jump, and then calculating the acid value using the formula.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Key Points for Wet Film Thickness Control in the Preparation of Fluorocarbon Coatings for Photovoltaic Backsheets Using Automatic Film Coating Machines
This article introduces the key points of controlling wet film thickness in the preparation of fluorocarbon coatings for photovoltaic backsheets using an automatic coating machine. Wet film thickness directly affects the performance and uniformity of the coating after curing, making its control crucial.
Alignment Accuracy Control Method for Four-Sided Preparator When Used with Automatic Coating Machine
This article explores the alignment accuracy control when using a four-sided preparator in conjunction with an automatic coating machine. Alignment accuracy directly affects the uniformity of the coating and the reliability of detection.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Programmable Automatic Film Coating Machine: Application Techniques of Multi-Speed Function in Gradient Coating Preparation