Tissue Paper Air Permeability Tester

The sanitary paper air permeability tester evaluates the breathability of paper by measuring the rate at which air passes through it. The instrument creates a pressure difference on both sides of the sample and records the volume of gas passing through per unit of time. This data reflects the softness and comfort of the sanitary paper in use and is applied in quality control during production.
Selection
When selecting, focus on the measurement range covering common toilet paper specifications, and the pressure difference control system should be stable. The detection accuracy must meet industry standards, and the operation interface should be user-friendly. Consider the applicability of the sample fixture, equipment maintenance cycles, and consumable costs. Ensure compliance with local testing regulations and requirements.
Measurement method

Terms

Standards

Instruments

Measurement range 0~ 1000ml/min or 0~ 17µm/(Pa · s), test area 10.0 +/- 0.05cm ², differential pressure accuracy +/- 0.01kPa, clamp ring coaxiality less than 0.05mm, suitable for medium Air Permeability paper testing.

$ 961.00

Suitable for 1 × 10-2 - 1 × 102um/(Pa. S) Air Permeability Range, Measurement accuracy of +/- 1ml (< 100ml), 304 stainless steel fixture and silicone sealing to ensure long-term corrosion resistance and sealing, support multi-gear measurement.

$ 1009.00

Measurement range 0~ 1000ml/min, pressure difference 0.1~ 2.0kpa, stainless steel end cap and pure copper valve anti-corrosion structure, built-in fixture to avoid rubber pad peeling, suitable for a variety of materials Air Permeability accurate test.

$ 1200.00

Measurement range 0~ 1000ml/min, test area 10cm ², test area pressure difference 1kPa, suitable for a variety of industrial paper ventilation performance detection.

$ 935.00

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

Vacuum Level 100 or 200 mm water column constant test, Measurement range 0-1000ml/min, test area 10cm ², support a variety of paper ventilation performance evaluation.

$ 1151.00

Measurement range 0~ 1000ml/min, test area pressure accuracy of +/- 0.01kPa, equipped with 10cm ² standard test area and 35.68mm clamping ring, support different duration test.

$ 1098.00

Measurement range 0~ 2500mL/min, accuracy of 0.01μm/Pa • s, support a variety of test methods, automated operation to ensure accurate and reliable results.

$ 4269.00

The test area is 30cm ², suitable for self-supporting and non-self-supporting coating testing, and the permeability of water vapor or Miscellaneous gaseous substances to the film can be determined by the wet Cup method or the dry Cup method.

$ 135.00

The test area is 50cm ², which supports two test modes of wet Cup method and dry Cup method, which can measure the permeability of water vapor and Miscellaneous gaseous substances to the film, and is suitable for coating performance evaluation under different environment conditions.

$ 196.00

Test area of 10cm ², in line with a number of international standards, support self-supporting and non-self-supporting coating testing, can be measured by wet Cup method and dry Cup method of water vapor permeability, suitable for different environmental conditions.

$ 119.00

Sampling accuracy of +/- 0.2mm, can handle 0.1-1 film thickness samples, equipped with upper and lower knife design to ensure that the incision is neat and not fluffy, and supports multi-layer punching operation.

$ 551.00

Speed up to 30000rpm, the maximum processing viscosity of 10000mPa.s, the use of claw high shear head structure and triple safety protection, can quickly homogenize tissue samples, stator and rotor interchangeable cost savings.

$ 1263.00

Adopt immersion coating method, mechanical speed 1.2m/min adjustable, Temperature range 50-150 ℃ +/- 3 ℃, equipped with Air-Cooled system and air knife cutting, support automatic tension control, ensure coiling edge uniformity +/- 3.0mm.

$ 35574.00

The instrument is dedicated to measuring the thickness of sheet materials. The measurement head contacts the workpiece to compress about 0.15mm and then has a zero reading. It can switch different display formats to meet the standard testing requirements.

$ 461.00

Articles

Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
Application of Tensile Stiffness Tester in Tissue Paper and Packaging Paper.
The tensile stiffness tester is used to measure the resistance of thin paper and packaging paper to bending. Its principle is based on the theory of material bending, and the stiffness value is calculated using a formula. Thin papers, such as toilet paper, require lower stiffness to ensure softness, while packaging papers, such as paper bag paper, require higher stiffness to provide support.
What is the difference between the Bendtsen method and the Gurley method for measuring paper air permeability using an air permeability tester?
The air permeability of paper is a key indicator for evaluating its structural compactness and suitability, especially crucial in fields such as packaging, filtration, and specialty papers. The Bendtsen and Gurley methods are two classic and widely used techniques for determining paper permeability.