Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.
Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.
Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.
Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.
Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.
Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.
Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.
Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.
Using microcomputer temperature control self-tuning PID adjustment technology, temperature control accuracy +/- 0.05 ℃, Temperature Fluctuation is small; fully enclosed Compressor refrigeration system, high refrigeration efficiency, low noise; professional circulation mixing design, pump Flow rate 10L/min, to ensure that the liquid in the Tank is evenly distributed and smooth.
Adopt microcomputer temperature control self-tuning PID adjustment, temperature control accuracy +/- 0.05 ℃, Temperature Fluctuation is small; Fully enclosed Compressor refrigeration, low noise, high efficiency; Domestic circulation pump Flow rate 10L/min to ensure uniform and smooth heat exchange of liquid in the Tank.
Equipped with high and low temperature thermostatic cell, Temperature range 0-110 ℃, PT100 Probe real-time monitoring, liquid temperature can be corrected to ensure the accuracy of test data.
Adopting microcomputer temperature control self-tuning PID adjustment technology, the temperature control accuracy reaches +/- 0.05 ℃, and the temperature fluctuation is small; with internal and external circulation function, pump Flow rate 10L/min, to ensure uniform temperature in the Tank; fully enclosed Compressor refrigeration, high efficiency and low noise, Safety protection function is perfect.