Magnetic Stirring High Temperature Thermostat

The magnetic stirring high-temperature thermostatic bath heats the conductive medium through electric heating tubes and uses magnetic coupling to drive the stirrer to rotate, achieving uniform mixing. It is used for constant-temperature heating and stirring of laboratory samples and is commonly employed in scenarios requiring temperature-controlled mixing, such as chemical reactions and material synthesis.
Selection
When selecting, ensure the temperature range covers experimental needs, temperature control precision matches sample sensitivity, and tank capacity accommodates container sizes. Magnetic stirring speed should meet mixing requirements, material corrosion resistance aligns with medium characteristics, and safety protection functions ensure stable operation.

Terms

Standards

Instruments

Four-hole independent magnetic stirring can be stepless speed regulation and display Rotation speed, Temperature range 15~ 120 ℃, Temperature Fluctuation +/- 0.05 ℃, 4-sided Glass design is easy to observe sample changes.

$ 1492.00

4-Sided Glass design is easy to observe sample changes, four-hole independent temperature control accuracy +/- 0.05 ℃, magnetic stirring can be stepless speed regulation, accelerate liquid temperature transfer, achieve rapid uniform heating.

$ 1944.00

Can achieve -80 ℃ low temperature control, built-in two-stage magnetic stirring system, Speed range 100-1200RPM, equipped with high temperature and over-temperature protection functions, environmentally friendly refrigerant to ensure safe operation.

$ 4222.00

Driven by brushless DC motor, Max. stirring Capacity up to 10 liters, stirring speed range of 150-2000rpm, with super stirring force, suitable for high viscosity liquid stirring.

$ 227.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

High-power DC brushless three-phase motor, no spark, high efficiency, large torque, Max. stirring Capacity 50L, Rotation speed 50~ 1500rpm adjustable, suitable for low to high viscosity liquids, strong magnetic design to improve stirring efficiency.

$ 543.00

Max.stirring Capacity 5L, stirring speed 0~ 2000rpm, using strong magnetic drive, suitable for medium capacity stirring, smooth and continuous operation.

$ 170.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, suitable for large-capacity stirring, and equipped with digital display Rotation speed.

$ 520.00

Three-phase motor closed-loop control to achieve constant speed operation, low speed up to 50rpm, Max. stirring Capacity 10L, motor torque 80mN · M, suitable for high viscosity medium stirring, the shell stainless steel design is lighter.

$ 233.00

Driven by three-phase brushless DC motor, torque up to 100W, strong magnetic force, Max. stirring Capacity 50L, Speed range 60~ 1400rpm, suitable for large-capacity stirring, strong and durable structure.

$ 507.00

Rotation speed is smooth and not affected by Power supply frequency by brushless DC motor, Max. stirring Capacity is up to 20L, strong magnetic force and strong structure, high power voltage regulation output and Rotation speed and voltage display function.

$ 322.00

Brushless DC motor to achieve 100-2000rpm smooth stirring, double heating control loop to ensure temperature stability, aluminum die-casting ceramic coating plate with abrasion resistance and corrosion resistance, Max. stirring Capacity up to 20L.

$ 577.00

Adopt microcomputer PID temperature control, temperature control accuracy +/- 0.5 ℃, ensure temperature stability. Magnetic stirring output torque, keep Rotation speed constant, over-temperature sound and light alarm to protect sample safety.

$ 1016.00

Maximum stirring capacity 3 liters, stirring speed 200~ 1800rpm stepless speed regulation, Heating power 450W, Temperature range RT + 5~ 320 ℃, using aluminum alloy die-casting shell, high temperature corrosion resistance easy to clean.

$ 311.00

With magnetic stirring function, the maximum stirring capacity of 2000ml, Speed range 200-2500rpm, vibration range 4.5mm, support point and continuous operation mode switching.

$ 359.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.