The strong light incubator simulates natural environments by controlling light intensity and temperature, and is used for experiments such as plant growth and material aging, with applications in agricultural and industrial testing.
Selection
When selecting a high-intensity light incubator, factors such as the light range, temperature control accuracy, chamber size, and energy consumption must be considered to match experimental needs and budget, ensuring equipment stability and ease of maintenance.

Terms

Standards

Instruments

Adopt five-stage adjustable lighting system, Illumrination degree 0~ 6000LX, Temperature range 10~ 65 ℃. Equipped with ALLCOLD ™ equilibrate refrigeration and ALLFLOW ™ air circulation to ensure uniform and stable temperature and support continuous operation.

$ 3412.00

Using ALLCOLD ™ equilibrate refrigeration technology to solve the problem of frosting, equipped with a five-stage adjustable lighting system to ensure constant temperature. Temperature control accuracy +/- 0.5 ° C, volume 250L, support continuous operation and remote monitoring.

$ 3974.00

Using three strong magnets to ensure stable positioning, the vertical circular drill bit achieves 90-degree accurate cutting through the angle swirl/spin mechanism, the kit diaMeter is 20mm, the height is 15cm, and the aluminum material is light and durable.

$ 1488.00

Adopting mirror stainless steel liner and unique air duct circulation to ensure Temperature Uniformity +/- 1.5 ℃, 24-stage program can be set to simulate day and night changes, support 0~ 12000LX four-level adjustable light, safe temperature limit alarm.

$ 1369.00

With ALLCOLD ™ equilibrate refrigeration and ALLFLOW ™ air circulation system, Temperature range 10~ 65 ℃, Illumrination degree five-stage adjustable to 6000LX, double-decked insulation and Pro-Bright ™ lighting system to ensure constant temperature and uniform lighting.

$ 5410.00

Using brushless DC motor to achieve stepless speed regulation of 0~ 1500rpm, equipped with strong magnetic steel to ensure strong stirring force and stable Rotation speed, Temperature range RT +~ 150 ℃, Heating power 360W adjustable, support mechanical timing 20~ 120min.

$ 212.00

Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.

$ 1427.00

Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.

$ 2315.00

Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, surrounded by 316L stainless steel material comprehensive corrosion resistance.

$ 643.00

Microcrystalline Glass panel is resistant to strong acid and alkali, low expansion coefficient to ensure no deformation at high temperature; Operating temperature 450 ℃, ceramic fiber insulation material is lightweight and efficient, and 316L stainless steel around is corrosion resistant.

$ 612.00

Microcrystalline Glass panel resistant to strong acid and alkali, low expansion coefficient to ensure high temperature without deformation, the highest Operating temperature 450 ℃, 316L stainless steel material comprehensive anti-corrosion, ceramic fiber insulation material lightweight and efficient.

$ 403.00

The mirror stainless steel liner is easy to clean, intelligent programmable control 24-stage program, Temperature Uniformity +/- 1 ℃, Illumrination degree 0~ 10000LX four-level adjustable, unique air duct to ensure uniform air supply does not hurt seedlings, temperature limit alarm to ensure safety.

$ 1116.00

24-Stage program can be set to simulate day and night temperature changes, Illumrination degree 0~ 25000LX four-level adjustable, unique air duct to ensure uniform temperature and do not blow seedlings, independent temperature limit alarm system to ensure safe operation.

$ 1942.00

Light spectrum LED light source, support sample surface free positioning measurement, repeability accuracy ≤ E * ab ≤ 0.07, Measurement speed of only 1.0 seconds, lightweight and portable.

$ 2623.00

Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.

$ 5850.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Turbidity meter selection: Basis for choosing light source type and measurement accuracy.
This article mainly introduces how to select a turbidity meter based on its light source type and measurement accuracy.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Application of Laboratory Coating Machines in the Coating of Optical-Grade PET Anti-Reflection Coatings
This article discusses the application of laboratory coating machines in the preparation of anti-reflective coatings on optical-grade PET substrates. By controlling parameters such as coating speed and gap, the coating machine enables precise adjustment of coating thickness, thereby enhancing light transmittance and reducing reflection.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.
Light source configuration and color matching environment requirements in the selection of standard light boxes
This article discusses how to choose a standard light booth, focusing mainly on the light source configuration and observation environment.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.